Document Outline

1
GLT540L16
ADVANCED
4M (2-Bank x 131072-Word x 16-Bit) Synchronous DRAM
F
EATURES
x
Single 3.3 V
±
0.3 V power supply
x
Clock frequency 100 MHz / 125 MHz / 143 MHz/
166 MHz
x
Fully synchronous operation referenced to clock
rising edge
x
Dual bank operation controlled by BA (Bank
Address)
x
CAS latency- 1 / 2 / 3 (programmable)
x
Burst length- 1 / 2 / 4 / 8 & Full Page (programmable)
x
Burst type- sequential / interleave (programmable)
x
Byte control by DQMU and DQML
x
Column access - random
x
Auto precharge / All bank precharge controlled by
A[8]
x
Auto refresh and Self refresh
x
1024 refresh cycles / 16 ms
x
LVTTL Interface
x
400-mil, 50-Pin Thin Small Outline Package (TSOP II)
with 0.8 mm lead pitch
x
Single write option
G
ENERAL
D
ESCRIPTION
The GLT540L16 is a 2-bank x 131072-word x 16-bit Syn-
chronous DRAM, with LVTTL interface. All inputs and
outputs are referenced to the rising edge of CLK. The
GLT540L16 achieves very high speed data rate up to
166 MHz.
March 2000 (Rev. 0)
2
G-LINK Technology
March 2000 (Rev. 0)
F
UNCTIONAL
B
LOCK
D
IAGRAM
A[8:0]
DQ[15:0]
Figure 1. 4M (2-Bank x 131072-Word x 16-Bit) Synchronous DRAM
Control Circuitry
Address Buffer
BA
CLK
CKE
CS
RAS
Clock Buffer
Control
Signal Buffer
CAS
WE
DQML
DQMU
Mode
Register
Memory Array
Bank #0
Memory Array
Bank #1
I/O Buffer
Signal Description
Signal
Type
Description
CLK
Input
Master Clock: All other inputs are referenced to the rising edge of CLK.
CKE
Input
Clock Enable: CKE controls internal clock. When CKE is low, internal clock for the following cycle is ceased. CKE
is also used to select auto / self refresh. After self refresh mode is started, CKE becomes asynchronous input.
Self refresh is maintained as long as CKE is low.
CS
Input
Chip Select: When CS is high, any command means No Operation.
RAS, CAS, WE
Input
Combination of RAS, CAS, WE defines basic commands.
A[8:0]
Input
A[8:0] specify the Row / Column Address in conjunction with BA. The Row Address is specified by A[8:0]. The
Column Address is specified by A[7:0]. A[8] is also used to indicate precharge option. When A[8] is high at a read
/ write command, an auto precharge is performed. When A[8] is high at a precharge command, both banks are
precharged.
BA
Input
Bank Address: BA is not simply A[9]. BA specifies the bank to which a command is applied. BA must be set with
ACT, PRE, READ, WRITE commands.
DQ[15:0]
Input / Output
Data In and Data out are referenced to the rising edge of CLK.
DQML
Input
Lower Din[7:0] Mask / Lower Output[7:0] Disable: When DQML is high in burst write, lower Din[7:0] for the current
cycle is masked. When DQML is high in burst read, lower Dout[7:0] is disabled at the next but one cycle.
DQMU
Input
Upper Din[15:8] Mask / Upper Output[15:8] Disable: When DQMU is high in burst write, upper Din(8-15) for the
current cycle is masked. When DQMU is high in burst read, upper Dout[15:8] is disabled at the next but one
cycle.
V
DD
, V
SS
Power Supply
Power Supply for the memory array and peripheral circuitry.
V
DDQ
, V
SSQ
Power
Supply
V
DDQ
and V
SSQ
are supplied to the Output Buffers only.
3
G-LINK Technology
March 2000 (Rev. 0)
F
UNCTIONAL
D
ESCRIPTION
The GLT540L16 provides basic functions, bank (row) acti-
vate, burst read / write, bank (row) precharge, and auto /
self refresh. Each command is defined by control signals
of RAS, CAS and WE at CLK rising edge. In addition to 3
signals, CS, CKE and A[8] are used as chip select, refresh
option, and precharge option, respectively.
To know the detailed definition of commands, please see
the command truth table.
Activate (ACT) [RAS = L, CAS = WE = H]
ACT command activates a row in an idle bank indicated
by BA.
Read (READ) [RAS = H, CAS = L, WE = H]
READ command starts burst read from the active bank
indicated by BA. First output data appears after CAS
latency. When A[8] = H at this command, the bank is
deactivated after the burst read (auto-precharge, READA).
Write (WRITE) [RAS = H, CAS =WE = L]
WRITE command starts burst write to the active bank
indicated by BA. Total data length to be written is set by
burst length. When A[8] = H at this command, the bank is
deactivated after the burst write (auto-precharge,
WRITEA).
Precharge (PRE)
[RAS = L, CAS = H, WE = L]
PRE command deactivates the active bank indicated by
BA. This command also terminates burst read / write
operation. When A[8] = H at this command, both banks
are deactivated (precharge all, PREA).
Auto-Refresh (REFA)
[RAS = CAS = L, WE = CKE = H]
REFA command starts auto-refresh cycle. Refresh
address including bank address are generated internally.
After this command, the banks are precharged automati-
cally. Any other command should not be asserted until
t
RC
is met.
1. H = High Level, L = Low Level, V = Valid, X = Don't Care, n = CLK cycle number
CLK
CS
RAS
CAS
WE
CKE
A[8]
Chip Select: L=select, h=deselect
Command
Command
Command
Define Basic Commands
Refresh option @refresh command
Precharge Option @ precharge or read/write
command
Command Truth Table
[1]
Command
Mnemonic
CKE n-1
CKE n
CS
RAS
CAS
WE
BA
A 8
A[7:0]
Deselect
DESEL
H
X
H
X
X
X
X
X
X
No Operation
NOP
H
X
L
H
H
H
X
X
X
Row Address Entry & Bank Activate
ACT
H
X
L
L
H
H
V
V
V
Single Bank Precharge
PRE
H
X
L
L
H
L
V
L
X
Precharge All Banks
PREA
H
X
L
L
H
L
V
H
X
Column Address Entry & Write
WRITE
H
X
L
H
L
L
V
L
V
Column Address Entry & Write with Auto-Precharge
WRITEA
H
X
L
H
L
L
V
H
V
Column Address Entry & Read
READ
H
X
L
H
L
H
V
L
V
Column Address Entry & Read with Auto-Precharge
READA
H
X
L
H
L
H
V
H
V
Auto-Refresh
REFA
H
H
L
L
L
H
X
X
X
Self-Refresh Entry
REFS
H
L
L
L
L
H
X
X
X
Self-Refresh Exit
REFSX
L
H
H
X
X
X
X
X
X
L
H
L
H
H
H
X
X
X
Burst Terminate
TBST
H
X
L
H
H
L
X
X
X
Mode Register Set
MRS
H
X
L
L
L
L
L
L
V
4
G-LINK Technology
March 2000 (Rev. 0)
Function Truth Table
[1] [2]
Current State
CS
RAS
CAS
WE
Address
[3]
Command
Action
[4]
IDLE
H
X
X
X
X
DESEL
NOP
L
H
H
H
X
NOP
NOP
L
H
H
L
BA
TBST
ILLEGAL
[5]
L
H
L
X
BA, CA, A[8]
READ / WRITE
ILLEGAL
[5]
L
L
H
H
BA, RA
ACT
Bank Active, Latch RA
L
L
H
L
BA, A[8]
PRE / PREA
NOP
[6]
L
L
L
H
X
REFA
Auto-Refresh
[7]
L
L
L
L
Op-Code, Mode-Add
MRS
Mode Register Set
[7]
ROW ACTIVE
H
X
X
X
X
DESEL
NOP
L
H
H
H
X
NOP
NOP
L H H L
BA
TBST
NOP
L
H
L
H
BA, CA, A[8]
READ / READA
Begin Read, Latch CA, Determine Auto-
Precharge
L
H
L
L
BA, CA, A[8]
WRITE / WRITEA
Begin Write, Latch CA, Determine Auto-
Precharge
L
L
H
H
BA, RA
ACT
Bank Active / ILLEGAL
[5]
L
L
H
L
BA, A[8]
PRE / PREA
Precharge / Precharge All
L
L
L
H
X
REFA
ILLEGAL
L
L
L
L
Op-Code, Mode-Add
MRS
ILLEGAL
READ
H
X
X
X
X
DESEL
NOP (Continue Burst to END)
L
H
H
H
X
NOP
NOP (Continue Burst to END)
L
H
H
L
BA
TBST
Terminate Burst
L
H
L
H
BA, CA, A[8]
READ / READA
Terminate Burst, Latch CA, Begin New
Read, Determine Auto-Precharge
[8]
L
H
L
L
BA, CA, A[8]
WRITE / WRITEA
Terminate Burst, Latch CA, Begin Write,
Determine Auto-Precharge
[8]
L
L
H
H
BA, RA
ACT
Bank Active / ILLEGAL
[5]
L
L
H
L
BA, A[8]
PRE / PREA
Terminate Burst, Precharge
L
L
L
H
X
REFA
ILLEGAL
L
L
L
L
Op-Code, Mode-Add
MRS
ILLEGAL
WRITE
H
X
X
X
X
DESEL
NOP (Continue Burst to END)
L
H
H
H
X
NOP
NOP (Continue Burst to END)
L
H
H
L
BA
TBST
Terminate Burst
L
H
L
H
BA, CA, A[8]
READ / READA
Terminate Burst, Latch CA, Begin Read,
Determine Auto-Precharge
[8]
L
H
L
L
BA, CA, A[8]
WRITE / WRITEA
Terminate Burst, Latch CA, Begin Write,
Determine Auto-Precharge
[8]
L
L
H
H
BA, RA
ACT
Bank Active / ILLEGAL
[5]
L
L
H
L
BA, A[8]
PRE / PREA
Terminate Burst, Precharge
L
L
L
H
X
REFA
ILLEGAL
L
L
L
L
Op-Code, Mode-Add
MRS
ILLEGAL
5
G-LINK Technology
March 2000 (Rev. 0)
READ with AUTO
PRECHARGE
H
X
X
X
X
DESEL
NOP (Continue Burst to END)
L
H
H
H
X
NOP
NOP (Continue Burst to END)
L
H
H
L
BA
TBST
ILLEGAL
L
H
L
H
BA, CA, A[8]
READ / READA
ILLEGAL
L
H
L
L
BA, CA, A[8]
WRITE / WRITEA
ILLEGAL
L
L
H
H
BA, RA
ACT
Bank Active / ILLEGAL
[5]
L
L
H
L
BA, A[8]
PRE / PREA
ILLEGAL
[5]
L
L
L
H
X
REFA
ILLEGAL
L
L
L
L
Op-Code, Mode-Add
MRS
ILLEGAL
WRITE with AUTO
PRECHARGE
H
X
X
X
X
DESEL
NOP (Continue Burst to END)
L
H
H
H
X
NOP
NOP (Continue Burst to END)
L
H
H
L
BA
TBST
ILLEGAL
L
H
L
H
BA, CA, A[8]
READ / READA
ILLEGAL
L
H
L
L
BA, CA, A[8]
WRITE / WRITEA
ILLEGAL
L
L
H
H
BA, RA
ACT
Bank Active / ILLEGAL
[5]
L
L
H
L
BA, A[8]
PRE / PREA
ILLEGAL
[5]
L
L
L
H
X
REFA
ILLEGAL
L
L
L
L
Op-Code, Mode-Add
MRS
ILLEGAL
PRE -CHARGING
H
X
X
X
X
DESEL
NOP (Idle after t
RP
)
L
H
H
H
X
NOP
NOP (Idle after t
RP
)
L
H
H
L
BA
TBST
ILLEGAL
[5]
L
H
L
X
BA, CA, A[8]
READ / WRITE
ILLEGAL
[5]
L
L
H
H
BA, RA
ACT
ILLEGAL
[5]
L
L
H
L
BA, A[8]
PRE / PREA
NOP
[6]
(Idle after t
RP
)
L
L
L
H
X
REFA
ILLEGAL
L
L
L
L
Op-Code, Mode-Add
MRS
ILLEGAL
ROW ACTIVATING
H
X
X
X
X
DESEL
NOP (Row Active after t
RCD
)
L
H
H
H
X
NOP
NOP (Row Active after t
RCD
)
L
H
H
L
BA
TBST
ILLEGAL
[5]
L
H
L
X
BA, CA, A[8]
READ / WRITE
ILLEGAL
[5]
L
L
H
H
BA, RA
ACT
ILLEGAL
[5]
L
L
H
L
BA, A[8]
PRE / PREA
ILLEGAL
[5]
L
L
L
H
X
REFA
ILLEGAL
L
L
L
L
Op-Code, Mode-Add
MRS
ILLEGAL
WRITE RECOVERING
H
X
X
X
X
DESEL
NOP
L
H
H
H
X
NOP
NOP
L
H
H
L
BA
TBST
ILLEGAL
[5]
L
H
L
X
BA, CA, A[8]
READ / WRITE
ILLEGAL
[5]
L
L
H
H
BA, RA
ACT
ILLEGAL
[5]
L
L
H
L
BA, A[8]
PRE / PREA
ILLEGAL
[5]
L
L
L
H
X
REFA
ILLEGAL
L
L
L
L
Op-Code, Mode-Add
MRS
ILLEGAL
Function Truth Table
[1] [2]
(Continued)
Current State
CS
RAS
CAS
WE
Address
[3]
Command
Action
[4]
6
G-LINK Technology
March 2000 (Rev. 0)
1. H = High Level, L= Low Level, X = Don't Care.
2. All entries assume that CKE was High during the preceding clock cycle and the current clock cycle.
3. BA = Bank Address, RA = Row Address, CA = Column Address, NOP = No OPeration.
4. ILLEGAL = Device operation and/or data-integrity are not guaranteed.
5. ILLEGAL to bank in specified state; function may be legal in the bank indicated by BA, depending on the state of that bank.
6. NOP to bank precharging or in idle state. May precharge bank indicated by BA.
7. ILLEGAL if any bank is not idle.
8. Must satisfy bus contention, bus turn around, write recovery requirements.
REFRESHING
H
X
X
X
X
DESEL
NOP (Idle after t
RC
)
L
H
H
H
X
NOP
NOP (Idle after t
RC
)
L
H
H
L
BA
TBST
ILLEGAL
L
H
L
X
BA, CA, A[8]
READ / WRITE
ILLEGAL
L
L
H
H
BA, RA
ACT
ILLEGAL
L
L
H
L
BA, A[8]
PRE / PREA
ILLEGAL
L
L
L
H
X
REFA
ILLEGAL
L
L
L
L
Op-Code, Mode-Add
MRS
ILLEGAL
MODE REGISTER
SETTING
H
X
X
X
X
DESEL
NOP (Idle after t
RSC
)
L
H
H
H
X
NOP
NOP (Idle after t
RSC
)
L
H
H
L
BA
TBST
ILLEGAL
L
H
L
X
BA, CA, A[8]
READ / WRITE
ILLEGAL
L
L
H
H
BA, RA
ACT
ILLEGAL
L
L
H
L
BA, A[8]
PRE / PREA
ILLEGAL
L
L
L
H
X
REFA
ILLEGAL
L
L
L
L
Op-Code, Mode-Add
MRS
ILLEGAL
Function Truth Table
[1] [2]
(Continued)
Current State
CS
RAS
CAS
WE
Address
[3]
Command
Action
[4]
7
G-LINK Technology
March 2000 (Rev. 0)
1. H = High Level, L= Low Level, X = Don't Care.
2. CKE Low to High transition will re-enable CLK and other inputs asynchronously. A minimum setup time must be satisfied before any command other than EXIT.
3. Power-Down and Self-Refresh can be entered only from the All Banks Idle State.
4. Must be legal command.
Function Truth Table for CKE
[1]
Current State
CKE n-1
CKE n
CS
RAS
CAS
WE
Add
Action
SELF-REFRESH
[2]
H
X
X
X
X
X
X
INVALID
L
H
H
X
X
X
X
Exit Self-Refresh (Idle after t
RC
)
L
H
L
H
H
H
X
Exit Self-Refresh (Idle after t
RC
)
L
H
L
H
H
L
X
ILLEGAL
L
H
L
H
L
X
X
ILLEGAL
L
H
L
L
X
X
X
ILLEGAL
L
L
X
X
X
X
X
NOP (Maintain Self-Refresh)
POWER DOWN
H
X
X
X
X
X
X
INVALID
L
H
X
X
X
X
X
Exit Power Down to Idle
L
L
X
X
X
X
X
NOP (Maintain Self-Refresh)
ALL BANKS IDLE
[3]
H
H
X
X
X
X
X
Refer to Function Truth Table
H
L
L
L
L
H
X
Enter Self-Refresh
H
L
H
X
X
X
X
Enter Power Down
H
L
L
H
H
H
X
Enter Power Down
H
L
L
H
H
L
X
ILLEGAL
H
L
L
H
L
X
X
ILLEGAL
H
L
L
L
X
X
X
ILLEGAL
L
X
X
X
X
X
X
Refer to Current State = Power Down
ANY STATE other than
listed above
H
H
X
X
X
X
X
Refer to Function Truth Table
H
L
X
X
X
X
X
Begin CLK Suspend at Next Cycle
[4]
L
H
X
X
X
X
X
Exit CLK Suspend at Next Cycle
[4]
L
L
X
X
X
X
X
Maintain CLK Suspend
8
G-LINK Technology
March 2000 (Rev. 0)
Power On Sequence
Before starting normal operation, the following power on
sequence is necessary to prevent damage or malfunction.
1. Apply power and start clock. Attempt to maintain
CKE high, DQMU / DQML high and NOP condition
at the inputs.
2. Maintain stable power, stable clock, and NOP input
conditions for a minimum of 200
m
s.
3. Issue precharge commands for all banks. (PRE or
PREA)
4. After all banks become idle state (after t
RP
), issue 2
or more auto-refresh commands.
5. Issue a mode register set command to initialize the
mode register.
After this sequence, the SDRAM is idle state and ready for
normal operation.
MODE
REGISTER
SET
PRECHARGE
POWER ON
POWER
APPLIED
PRE
SELF
REFRESH
IDLE
AUTO
REFRESH
CLK
SUSPEND
ROW ACTIVE
WRITE
SUSPEND
WRITE
READ
READ
SUSPEND
WRITE A
SUSPEND
WRITE A
READ A
READ A
SUSPEND
PRE
PRE
PRE
CKEH
CKEL
CKEL
CKEH
CKEL
CKEH
CKEL
CKEH
WRITE A
READE A
WRITE A
READE A
WRITE
READ
WRITE A
READE A
WRITE
READ
POWER
DOWN
CKEL
CKEH
ACT
CKEL
CKEH
MRS
REFA
REFS
REFSX
Automatic Sequence
Command Sequence
Figure 2. Simplified State Diagram
TBST
TBST
9
G-LINK Technology
March 2000 (Rev. 0)
Mode Register
Burst Length, Burst Type and CAS Latency can be pro-
grammed by setting the mode register (MRS). The mode
register stores these data until the next MRS command,
which may be issued when both banks are in idle state.
After t
RSC
from a MRS command, the SDRAM is ready for
new command.
CLK
CS
RAS
CAS
WE
BA, A[8:0]
BA
A8
A7
A6
A5
A4
A3
A2 A1
A0
WBL 0 Ø
LTMODE
BT
BL
0
0
0
CL
0
0
1
CAS LATENCY
0
0
1
1
1
1
1
1
0
0
1
1
0
1
0
1
0
1
R
1
2
3
R
R
R
R
0
0
0
BL
0
0
1
0
0
1
1
1
1
1
1
0
0
1
1
0
1
0
1
0
1
BT = 0
BT = 1
1
2
4
8
R
R
R
Full Page
1
2
4
8
R
R
R
R
1
SEQUENTIAL
INTERLEAVED
0
BURST
TYPE
BURST
LENGTH
LATENCY
MODE
Write Burst Length (WBL)
BA
0
1
Length
= BL specified
Single bit (BL = 1)
CLK
Command
READ
Address
DQ
WRITE
Q0
Q1
Q3
Y
Q2
D0
D1
D3
D2
CAS Latency
Burst Length
Burst Length
Y
Burst Type
Initial
Address
BL
Column Addressing
A2
A1
A0
Sequential
Interleaved
0
0
0
8
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
0
1
1
2
3
4
5
6
7
0
1
0
3
2
5
4
7
6
0
1
0
2
3
4
5
6
7
0
1
2
3
0
1
6
7
4
5
0
1
1
3
4
5
6
7
0
1
2
3
2
1
0
7
6
5
4
1
0
0
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
1
0
1
5
6
7
0
1
2
3
4
5
4
7
6
1
0
3
2
1
1
0
6
7
0
1
2
3
4
5
6
7
4
5
2
3
0
1
1
1
1
7
0
1
2
3
4
5
6
7
6
5
4
3
2
1
0
­
0
0
4
0
1
2
3
0
1
2
3
­
0
1
1
2
3
0
1
0
3
2
­
1
0
2
3
0
1
2
3
0
1
­
1
1
3
0
1
2
3
2
1
0
­
­
0
2
0
1
0
1
­
­
1
1
0
1
0
10
G-LINK Technology
March 2000 (Rev. 0)
O
PERATIONAL
D
ESCRIPTION
Bank Activate
The SDRAM has two independent banks. Each bank is
activated by the ACT command with the bank address
(BA). A row is indicated by the row address A[8:0] The
minimum activation interval between one bank and the
other bank is t
RRD
.
Precharge
The PRE command deactivates the bank indicated by BA.
When both banks are active, the precharge all command
(PREA, PRE + A[8] = H) is available to deactivate them at
the same time. After t
RP
from the precharge, an ACT com-
mand can be issued.
CLK
Figure 3. Bank Activation and Precharge All (BL=4, CL=3)
Command
A[7:0]
A[8]
BA
DQ
ACT
ACT
READ
PRE
ACT
Xa
Xa
0
Xb
Ya
Xb
0
0
1
1
Xb
Xb
1
Qa2
Qa1
Qa0
Qa3
Precharge All
t
RRD
t
RAS
t
RP
11
G-LINK Technology
March 2000 (Rev. 0)
Read
After t
RCD
from the bank activation, a READ command
can be issued. 1st output data is available after the CAS
Latency from the READ, followed by (BL-1) consecutive
data when the Burst Length is BL. The start address is
specified by A[7:0], and the address sequence of burst
data is defined by the Burst Type. A READ command may
be applied to any active bank, so the row precharge time
(t
RP
) can be hidden behind continuous output data (in
case of BL = 4) by interleaving the dual banks. When A[8]
is high at a READ command, the auto-precharge (READA)
is performed. Any command (READ, WRITE, PRE, ACT) to
the same bank is inhibited till the internal precharge is
complete. The internal precharge start timing depends on
CAS Latency. The next ACT command can be issued after
t
RP
from the internal precharge timing.
CLK
Figure 4. Dual Bank Interleaving READ (BL=4, CL=3)
Command
A[7:0]
A[8]
BA
DQ
ACT
READ
ACT
PRE
Qa2
Qa1
Qa0
Qa3
READ
Xa
Ya
Xb
Yb
Xa
0
Xb
0
0
0
0
1
0
1
Qb0
Qb1
Qb2
t
RCD
CAS Latency
Burst Length
CLK
Figure 5. READ with Auto-Precharge (BL=4, CL=3)
Command
A[7:0]
A[8]
BA
DQ
ACT
READ A
ACT
Qa2
Qa1
Qa0
Qa3
t
RCD
Xa
Y
Xa
Xa
1
Xa
0
0
0
t
RP
Internal Precharge begins
CLK
Figure 6. READ Auto-Precharge Timing (BL=4)
Command
CL=3 DQ
CL=2 DQ
ACT
READ A
Internal Precharge Start Timing
Qa2
Qa1
Qa0
Qa3
Qa2
Qa1
Qa0
Qa3
12
G-LINK Technology
March 2000 (Rev. 0)
Write
After t
RCD
from the bank activation, a WRITE command
can be issued. 1st input data is set at the same cycle as
the WRITE. Following (BL-1) data are written into the
RAM, when the Burst Length is BL. The start address is
specified by A[7:0], and the address sequence of burst
data is defined by the Burst Type. A WRITE command
may be applied to any active bank, so the row precharge
time (t
RP
) can be hidden behind continuous input data (in
case of BL = 4) by interleaving the dual banks. From the
last input data to the PRE command, the write recovery
time (t
RDL
) is required. When A[8] is high at a WRITE com-
mand, the auto-precharge (WRITEA) is performed. Any
command (READ, WRITE, PRE, ACT) to the same bank is
inhibited till the internal precharge is complete. The inter-
nal precharge begins at t
WR
after the last input data cycle.
The next ACT command can be issued after t
RP
from the
internal precharge timing.
CLK
Figure 7. Dual Bank Interleaving WRITE (BL=4)
Command
A[7:0]
A[8]
BA
DQ
t
RCD
t
RCD
Burst Length
t
RDL
(1 CLK)
Da2
Da1
Da0
Da3
ACT
WRITE
ACT
PRE
WRITE
Xa
Y
Xb
Y
Xa
0
Xb
0
0
0
0
1
0
1
Db1
Db0
Db3
Db2
CLK
Figure 8. WRITE with Auto-Precharge (BL=4)
Command
A[7:0]
A[8]
BA
Internal Precharge Begins
DQ
t
RCD
t
RP
t
RDL
Da2
Da1
Da0
Da3
ACT
WRITE
ACT
Xa
Y
Xa
Xa
1
Xa
0
0
0
13
G-LINK Technology
March 2000 (Rev. 0)
Burst Interruption
[Read Interrupted by Read]
The burst read operation can be interrupted by a new
read of the same or the other bank. GLT540L16 allows
random column access. READ to READ interval is 1 CLK
minimum.
[Read Interrupted by Write]
Burst read operation can be interrupted by write of the
same or the other bank. Random column access is
allowed. In this case, the DQ should be controlled ade-
quately by using the DQMU / DQML to prevent the bus
contention. The output is disabled automatically 2 cycles
after WRITE assertion.
CLK
Figure 9. READ Interrupted by READ (BL=4, CL=3)
Command
A[7:0]
A[8]
BA
Internal Precharge Start Timing
DQ
0
Qj1
Qj0
Qi0
Qk0
READ
READ
READ
Qk2
Qk1
Ql1
Ql0
READ
Yi
Yk
Yl
Yj
0
0
0
0
0
1
0
Ql2
Ql3
CLK
Command
A[7:0]
A[8]
BA
DQMU, DQML
Figure 10. READ Interrupted by WRITE (BL=4, CL=3)
Q
D
Dj0
Qi0
Dj1
READ
Dj3
Dj2
WRITE
Yi
Yj
0
0
0
0
DQM U/ DQML control
Write control
14
G-LINK Technology
March 2000 (Rev. 0)
[Read Interrupted by Precharge]
Burst read operation can be interrupted by precharge of
the same bank. READ to PRE interval is minimum 1 CLK.
A PRE command disables the data output, depending on
the CAS Latency. The figure below shows examples,
when the data-out is terminated.
Figure 11. READ Interrupted by Precharge (BL=4)
CLK
Command
DQ
Command
DQ
Command
DQ
Command
DQ
Command
DQ
Command
DQ
CL=2
CL=3
Q 0
READ
PRE
READ
PRE
READ
PRE
READ
PRE
READ
PRE
READ
PRE
Q 0
Q 1
Q 2
Q 3
Q 0
Q 1
Q 2
Q 0
Q 0
Q 1
Q 2
Q 3
Q 0
Q 1
Q 2
15
G-LINK Technology
March 2000 (Rev. 0)
[Read Interrupted by Burst Terminate]
Similarly to the precharge, burst terminate command can
interrupt burst read operation and disable the data out-
put. READ to TBST interval is minimum 1 CLK. The figure
below shows examples, when the data-out is terminated.
CLK
Command
DQ
Command
DQ
Command
Figure 12. READ Interrupted by Burst Terminate (BL=4)
DQ
Command
DQ
Command
DQ
Command
DQ
CL=2
CL=3
Q 0
READ
TBST
Q 1
Q 2
Q 3
READ
TBST
Q 0
Q 1
Q 2
READ
Q 0
TBST
Q 0
Q 1
Q 2
Q 3
Q 0
Q 1
Q 2
Q 0
READ
TBST
READ
TBST
READ
TBST
16
G-LINK Technology
March 2000 (Rev. 0)
[Write Interrupted by Write]
Burst write operation can be interrupted by new write of
the same or the other bank. Random column access is
allowed. WRITE to WRITE interval is minimum 1 CLK.
[Write Interrupted by Read]
Burst write operation can be interrupted by read of the
same or the other bank. Random column access is
allowed. WRITE to READ interval is minimum 1 CLK. The
input data on DQ at the interrupting READ cycle is
"don't care". Using the DQMU / DQML to prevent the bus
contention is optional.
CLK
Command
A[7:0]
A[8]
BA
DQ
Figure 13. WRITE Interrupted by WRITE (BL=4)
Dj1
Dj0
Di0
Dk0
WRITE
Dk2
Dk1
Dl1
Dl0
Yi
Yk
Yl
Yj
0
0
0
0
0
1
0
0
Dl2
Dl3
WRITE
WRITE
WRITE
CLK
Command
DQ
Figure 14. WRITE interrupted by READ (BL=4, CL=3)
A[7:0]
A[8]
BA
DQMU, DQML
WRITE
READ
0
0
Di0
Qj1
Qj0
Dk0
Dk1
WRITE
READ
Yi
Yj
Yk
Yl
0
0
0
0
0
1
Ql0
17
G-LINK Technology
March 2000 (Rev. 0)
[Write Interrupted by Precharge]
Burst write operation can be interrupted by precharge of
the same bank. Random column access is allowed.
Because the write recovery time (t
RDL
) is required
between the last input data and the next PRE, 3rd data
should be masked with DQMU / DQML shown as below.
[Write Interrupted by Burst Terminate]
Burst terminate command can terminate burst write
operation. In this case, the write recovery time is not
required and the bank remains active. The figure below
shows the case 3 words of data are written. Random col-
umn access is allowed. WRITE to TBST interval is
minimum 1 CLK.
CLK
Command
DQ
Figure 15. WRITE Interrupted by Precharge (BL=4)
A[7:0]
A[8]
BA
DQMU, DQML
This data should be masked to satisfy t
RDL
requirement.
0
0
Di0
Ya
Xb
WRITE
PRE
ACT
0
Xb
0
0
Di1
CLK
Command
DQ
Figure 16. WRITE Interrupted by Burst Terminate (BL=4)
A[7:0]
A[8]
BA
DQMU, DQML
Da0
Ya
WRITE
TBST
Da1
0
0
Da2
18
G-LINK Technology
March 2000 (Rev. 0)
Auto Refresh
Single cycle of auto-refresh is initiated with a REFA
(CS = RAS = CAS = L, WE = CKE = H) command. The
refresh address is generated internally. 1024 REFA cycles
within 16 ms refresh 4 Mbit memory cells. The auto-
refresh is performed on each bank alternately (ping-pong
refresh). Before performing an auto-refresh, both banks
must be in the idle state. Additional commands must not
be supplied to the device before t
RC
from the REFA
command.
Self Refresh
Self-refresh mode is entered by issuing a REFS command
(CS = RAS = CAS = L, WE = H, CKE = L). Once the self-
refresh is initiated, it is maintained as long as CKE is kept
low. During the self-refresh mode, CKE is asynchronous
and the only enabled input (but asynchronous), all other
inputs including CLK are disabled and ignored, and
power consumption due to synchronous inputs is saved.
To exit the self-refresh, supplying stable CLK inputs,
asserting DESEL or NOP command and then asserting
CKE (REFSX). After t
RC
from REFSX both banks are in the
idle state and a new command can be issued after t
RC
, but
DESEL or NOP commands must be asserted till then.
CLK
CS
A[8:0]
Figure 17. Auto Refresh
RAS
CAS
WE
CKE
BA
NOP or Deselect
Minimum t
RC
Auto Refresh on Bank 0
Auto Refresh on Bank 1
minimum t
RC
for recovery
CLK
CS
A[8:0]
Figure 18. Self-Refresh
RAS
CAS
WE
CKE
BA
Stable CLK
Self Refresh Entry
Self Refresh Exit
NOP
new command
X
0
19
G-LINK Technology
March 2000 (Rev. 0)
CLK Suspend
CKE controls the internal CLK at the following cycle.
Figure 19 and Figure 20 show how CKE works. By negat-
ing CKE, the next internal CLK is suspended. The purpose
of CLK suspend is power down, output suspend or input
suspend. CKE is a synchronous input except during the
self-refresh mode. CLK suspend can be performed either
when the banks are active or idle, but a command at the
following cycle is ignored.
ext. CLK
CKE
int. CLK
CLK
CKE
Figure 19. Power Down by CKE
Command
CKE
Command
Standby Power Down
Active Power Down
NOP
PRE
NOP
NOP
NOP
NOP
NOP
NOP
NOP
ACT
NOP
NOP
NOP
NOP
NOP
NOP
CLK
CKE
Figure 20. DQ Suspend by CKE
Command
DQ
WRITE
READ
D0
D1
D2
D3
Q0
Q1
Q2
Q3
20
G-LINK Technology
March 2000 (Rev. 0)
DQMU / DQML Control
DQMU / DQML is a dual function signal defined as the
data mask for writes and the output disable for reads.
During writes, DQMU / DQML masks upper / lower input
data word by word. DQMU / DQML to write mask latency
is 0. During reads, DQMU / DQML forces upper / lower
output to Hi-Z word by word. DQMU / DQML to output Hi-
Z latency is 2.
CLK
Command
Figure 21. DQMU / DQML Function
DQ[7:0]
DQMU
DQ[15:8]
DQML
Masked by DQML = High
Masked by DQMU = High
Disabled by DQMU =High
Disabled by DQML = High
D2
D0
D3
Q0
Q1
Q3
WRITE
READ
D1
D0
D3
Q0
Q3
Q2
21
G-LINK Technology
March 2000 (Rev. 0)
E
LECTRICAL
S
PECIFICATIONS
1. Stresses greater than those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress rating only, and functional operation
of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect reliability.
1. V
IH
(max) = 5.6 V for pulse width less than 3 ns.
2. V
IL
(min) = -2.0 V for pulse width less than 3 ns.
Absolute Maximum Ratings
[1]
Symbol
Parameter
Conditions
Ratings
Unit
V
DD
Supply Voltage
with respect to V
SS
-1.0 to 4.6
V
V
DDQ
Supply Voltage for Output
with respect to V
SSQ
-1.0 to 4.6
V
V
I
Input Voltage
with respect to V
SS
-1.0 to 4.6
V
V
O
Output Voltage
with respect to V
SSQ
-1.0 to 4.6
V
I
O
Output Current
50
mA
P
D
Power Dissipation
T
A
= 25
°C
1000
mW
T
OPR
Operating Temperature
0 to 70
°C
T
STG
Storage Temperature
-65 to 150
°C
Recommended Operating Conditions (T
A
= 0 to +70
°
C, unless otherwise noted)
Symbol
Parameter
Min
Typ
Max
Unit
V
DD
Supply Voltage
3.0
3.3
3.6
V
V
DDQ
Supply Voltage for Output
3.0
3.3
3.6
V
V
IH
[1]
High-Level Input Voltage all inputs
2.0
V
DDQ
+ 0.3
V
V
IL
[2]
Low-Level Input Voltage all inputs
-0.3
0.8
V
DC Characteristics (T
A
= 0 to +70
°
C, V
DD
= V
DDQ
= 3.3
±
0.3V, V
SS
= V
SSQ
= 0 V, unless otherwise noted)
Symbol
Parameter
Test Conditions
Min
Max
Unit
V
OH
High-Level Output Voltage
I
OH
= -2 mA
2.4
V
V
OL
Low-Level Output Voltage
I
OL
= 2 mA
0.4
V
I
OZ
Off-state Output Current
Q floating V
O
= 0 to V
DDQ
-10
10
mA
I
I
Input Current
V
IH
= 0 to V
DDQ
+ 0.3 V
-10
10
mA
Capacitance (T
A
= 0 to +70
°
C, V
DD
= V
DDQ
= 3.3
±
0.3 V, V
SS
= V
SSQ
= 0 V, unless otherwise noted)
Symbol
Parameter
Test Condition
Min
Max
Unit
C
I(A)
Input Capacitance, address pin
V
I
= V
SS
f = 1 MHz
V
I
= 25 mVrms
2.5
5
pF
C
I(C)
Input Capacitance, control pin
2.5
5
pF
C
I(K)
Input Capacitance, CLK pin
2.5
5
pF
C
I/O
Input Capacitance, I/O pin
4
7
pF
22
G-LINK Technology
March 2000 (Rev. 0)
1. Input Pulse Levels: 0.8 V to 2.0 V. Input Timing Measurement Level: 1.4 V.
Average Supply Current from V
DD
(T
A
= 0 to +70
°
C, V
DD
= V
DDQ
= 3.3
±
0.3 V, V
SS
= V
SSQ
= 0 V, unless otherwise noted)
Symbol
Parameter
Test Conditions
Rating (Max)
Unit
-6
-7
-8
-10
I
CC1S
Operating Current, Single Bank
t
RC
= min, t
CLK
= min, BL = 1, CL = 3
120
110
100
90
mA
I
CC1D
Operating Current, Dual Bank
t
RC
= min, t
CLK
= min, BL = 1, CL = 3
170
150
140
120
mA
I
CC2H
Standby Current, CKE = H
both banks idle, t
CLK
= min, CKE = H
20
20
20
20
mA
I
CC2L
Standby Current, CKE = L
both banks idle, t
CLK
= min, CKE = L
2
2
2
2
mA
I
CC3H
Active Standby Current, CKE = H
both banks active, t
CLK
= min, CKE = H
35
35
35
35
mA
I
CC3L
Active Standby Current, CKE = L
both banks active, t
CLK
= min, CKE = L
2
2
2
2
mA
I
CC4
Burst Current
t
CLK
= min, BL = 4, CL = 3, both banks active
150
140
130
120
mA
I
CC5
Auto-Refresh Current
t
RC
= min, t
CLK
= min
110
100
90
80
mA
I
CC6
Self-Refresh Current
CKE < 0.2 V
1
1
1
1
mA
Low Power
300
300
300
300
mA
AC Characteristics (T
A
= 0 to +70
°
C, V
DD
= V
DDQ
= 3.3
±
0.3 V, V
SS
= V
SSQ
= 0 V, unless otherwise noted)
[1]
Symbol
Parameter
-6
-7
-8
-10
Unit
Min
Max
Min
Max
Min
Max
Min
Max
t
CLK
CLK Cycle Time
CL=2
9
10
13
ns
CL=3 6
7
8
10
ns
t
CH
CLK High Pulse Width
2.0
2.5
3
3.5
ns
t
CL
CLK Low Pulse Width
2.0
2.5
3
3.5
ns
t
T
Transition Time of CLK
1
10
1
10
1
10
1
10
ns
t
IS
Input Setup Time (all inputs)
2
2.5
2.5
2.5
ns
t
IH
Input Hold Time (all inputs)
1
1
1
1
ns
t
RC
Row Cycle Time
60
63
72
90
ns
t
RCD
Row to Column Delay
18
21
24
30
ns
t
RAS
Row Active Time
42
100k
42
100k
48
100k
60
100k
ns
t
RP
Row Precharge Time
18
21
24
30
ns
t
CCD
Column Address to Column Address Delay
1
1
1
1
CLK
t
RRD
Act to Act Delay Time
2
2
2
2
CLK
t
RSC
Mode Register Set Cycle Time
2
2
2
2
CLK
t
RDL
Last Data-In to Row Precharge Delay
1
1
1
1
CLK
t
REF
Refresh Interval Time
16.4
16.4
16.4
16.4
ms
1.4V
CLK
Signal
1.4V
Any AC timing is ref-
erenced to the input
signal crossing
23
G-LINK Technology
March 2000 (Rev. 0)
Switching Characteristics (T
A
= 0 to +70
°
C, V
DD
= V
DDQ
= 3.3
±
0.3 V, V
SS
= V
SSQ
= 0 V unless otherwise noted)
Symbol
Parameter
-6
-7
-8
-10
Unit
Min
Max
Min
Max
Min
Max
Min
Max
t
AC
Access Time from CLK CL = 3
5.5
6
6
7
ns
t
OH
Output Hold Time from CLK
2
2.5
3
3
ns
t
OLZ
Delay Time, Output Low Impedance from CLK
1
1
1
1
ns
t
OHZ
Delay Time, Output High Impedance from CLK
5.5
6
6
7
ns
1.4V
CLK
DQ
1.4V
Output Timing Measurement Reference Point
1.4V
CLK
DQ
1.4V
t
AC
t
OH
t
OHZ
-
+
V
REF
= 1.4V
V
TT
= 1.4V
V
OUT
50
W
50 pF
(1)
Figure 22. Output Load Condition
1. For GLT540L16-6, -7, the Output Load is 30 pF.
24
G-LINK Technology
March 2000 (Rev. 0)
Figure 23. WRITE Cycle (single bank) BL=4
t
RCD
t
RDL
t
RAS
t
RP
t
RC
Xa
HIGH
Xb
Xb
Xa
D
D
D
D
CLK
CS
RAS
CAS
WE
CKE
DQMU, DQML
A[7:0]
A[8]
BA
DQ
ACT
B0
B0
B0
B0
WRITE
PRE
ACT
Yi
25
G-LINK Technology
March 2000 (Rev. 0)
Figure 24. WRITE Cycle (Dual Bank) BL=4
t
RCD
t
RDL
t
RAS
t
RC
Xa
Xa
Yb
Ya
Xb
Xb
Da0
Da1
Da2
Da3
Db0
Db1
Db2
Db3
t
RP
t
RCD
t
RRD
t
RAS
t
RDL
CLK
CS
RAS
CAS
WE
CKE
DQMU, DQML
A[7:0]
A[8]
BA
DQ
HIGH
ACT
B0
B0
B1
B1
B0
B1
WRITE
WRITE
ACT
PRE
PRE
26
G-LINK Technology
March 2000 (Rev. 0)
Figure 25. READ Cycle (Single Bank) BL=4, CL=3
t
RCD
t
RAS
t
RC
X
X
X
Y
t
RP
t
RCD
X2
CLK
CS
RAS
CAS
WE
CKE
DQMU, DQML
A[7:0]
A[8]
BA
DQ
Q
Q
Q
Q
ACT
READ
PRE
27
G-LINK Technology
March 2000 (Rev. 0)
Figure 26. READ Cycle (Dual Bank) BL=4, CL=3
t
RCD
Xa
Y
Y
Xb
Xa
Xb
Xa
Xa
t
RCD
t
RRD
t
RC
t
RAS
t
RAS
t
RP
CLK
CS
RAS
CAS
WE
CKE
DQMU, DQML
A[7:0]
A[8]
BA
DQ
Qa
Qa
Qa
Qa
Qb
Qb
Qb
Qb
ACT
READ
READ
PRE
ACT
28
G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
DQMU, DQML
A[7:0]
A[8]
BA
DQ
Figure 27. WRITE to READ (Single Bank) BL=4, CL=3
X
Y
Y
X
t
RAS
t
RCD
D
D
D
D
Q
Q
Q
Q
ACT
WRITE
READ
29
G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
DQMU, DQML
A[7:0]
A[8]
BA
DQ
Figure 28. WRITE to READ (Dual Bank) BL=4, CL=3
Xa
Y
Y
Xb
Xa
Xa
Xb
Xa
t
RCD
t
RRD
t
RC
t
RAS
t
RAS
t
RP
t
WR
t
RCD
Da
Da
Da
Da
Qb0
Qb1
Qb2
Qb3
ACT
WRITE
ACT
READ
PRE
PRE
ACT
30
G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
DQML
A[7:0]
A[8]
BA
DQ[7:0]
Figure 29. DQM Byte Control for WRITE 3030to READ (Single Bank) BL=4, CL=3
DQMU
DQ[15:8]
X
Y
Y
X
Q
t
RAS
t
RCD
D
D
D
D
D
D
Q
Q
Q
Q
Q
ACT
WRITE
READ
31
G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
DQMU, DQML
A[7:0]
A[8]
BA
DQ
Figure 30. READ to WRITE (Single Bank) BL=4, CL=3
Xa
Y
Y
Xa
t
RAS
t
RCD
t
WR
for output disable
D
D
D
Qa0
Qa1
D
READ
PRE
WRITE
PRE
32
G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
DQMU, DQML
A[7:0]
A[8]
BA
DQ
Figure 31. READ to WRITE (Dual Bank) BL=4, CL=3
for output disable
Xa
Y
Y
Xb
Xa
Xb
Xa
Xa
t
RC
t
RCD
t
RRD
t
RAS
t
RAS
t
RP
t
RCD
t
WR
Db
Db
Db
Qa
Qa
Db
ACT
READ
PRE
ACT
ACT
WRITE
PRE
33
G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
A[7:0]
A[8]
BA
DQ
Figure 32. Write with Auto-Precharge BL=4
DQMU, DQML
X
X
Y
X
X
t
RC33
t
RCD
t
WR
+ t
RP
Internal Precharge starts
this timing depends on BL
D
D
D
D
ACT
WRITE A
ACT
34
G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
A[7:0]
A[8]
BA
DQ
Figure 33. Read with Auto-Precharge BL=4, CL=3
DQMU, DQML
X
X
Y
X
X
Internal Precharge start s @ CL=3, BL=4
this timing depends on CL and BL
t
RC
t
RCD
t
RP
Q
Q
Q
Q
ACT
READ
ACT
35
G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
A[7:0]
A[8]
BA
DQ
Figure 34. Auto-Refresh
DQMU, DQML
If any bank is active, it
must be precharged
t
RC
t
RP
PRE A
REF S
REF S
36
G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
A[7:0]
A[8]
BA
DQ
Figure 35. Self-Refresh Entry
DQMU, DQML
If any bank is active, it
must be precharged
t
RP
PRE A
REF S
37
G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
A[7:0]
A[8]
BA
DQ
Figure 36. Self-Refresh Exit
DQMU, DQML
X
X
NOP or desel
t
RC
t
SRX
Internal CLK Re-start
ACT
38
G-LINK Technology
March 2000 (Rev. 0)
CLK
CS
RAS
CAS
WE
CKE
A[7:0]
A[8]
BA
DQ
Figure 37. Mode Register Set BL=4, CL=3
DQMU, DQML
X
Y
Mode
X
t
RP
t
RPC
t
RCD
If any bank is
active, it must be
precharged
Q
Q
Q
PRE A
MRS
ACT
READ
39
G-LINK Technology
March 2000 (Rev. 0)
P
ACKAGING
I
NFORMATION
Figure 38. 50-Pin 400 mil TSOP II Pin Assignment
V
DD
DQ0
V
SSQ
DQ2
DQ3
V
DDQ
DQ4
DQ5
V
SSQ
DQ6
DQML
WE
CAS
RAS
CS
BA
A8/AP
V
DDQ
DQ11
DQ10
V
SSQ
DQ9
DQ8
V
DDQ
NC
DQMU
CLK
NC
NC
A7
A6
A5
A4
V
SS
1
2
3
4
5
6
7
8
9
10
13
14
15
16
17
18
19
20
44
43
42
41
40
39
38
37
36
35
32
31
30
29
28
27
26
Top View
A0
A1
21
22
DQ7
V
DDQ
11
12
34
33
CKE
NC
23
24
25
45
46
47
48
49
50
A2
A3
V
DD
DQ12
DQ13
V
SSQ
DQ14
DQ15
V
SS
DQ1
40
G-LINK Technology
March 2000 (Rev. 0)
0.3 +0.1/-0.05
10.16
±
0.1
20.95
±
0.1
21.35 max.
0.8
0.125
+ 0.05
- 0.02
0.1
11.76
±
0.2
0.5
±
0.1
0.125
±
0.075
1.0
±
0.10
1
25
26
50
Detail A
Detail A
0
°
~10
°
Figure 39. 50-Pin 400 mil Plastic TSOP II Package Dimensions
41
G-LINK Technology
March 2000 (Rev. 0)
O
RDERING
I
NFO
GLT5160L16
Part Number
Mode
Cycle Time
Max Frequency
Interface
Package
GLT540L16-10TC
Synchronous
10
100 MHz
LVTTL
50-Pin 400 mil Plastic TSOP II
GLT540L16-8TC
Synchronous
8
125 MHz
LVTTL
50-Pin 400 mil Plastic TSOP II
GLT540L16-7TC
Synchronous
7
143 MHz
LVTTL
50-Pin 400 mil Plastic TSOP II
GLT 540L16-6TC
Synchronous
6
166MHz
LVTTL
50-Pin 400 mil Plastic TSOP ll
42
G-LINK Technology
March 2000 (Rev. 0)
43
G-LINK Technology
March 2000 (Rev. 0)
© 1999 G-LINK Technology
All rights reserved. No part of this document may be copied or reproduced in any form or by any means or transferred to any third party without the prior written consent of
G-LINK Technology.
Circuit diagrams utilizing G-LINK products are included as a means of illustrating typical semiconductor applications. Complete information sufficient for design purposes is
not necessarily given.
G-LINK Technology reserves the right to change products or specifications without notice.
The information contained in this document does not convey any license under copyrights, patent rights or trademarks claimed and owned by G-LINK or its subsidiaries.
G-LINK assumes no liability for G-LINK applications assistance, customer's product design, or infringement of patents arising from use of semiconductor devices in such
systems' designs. Nor does G-LINK warrant or represent that any patent right, copyright, or other intellectual property right of G-LINK covering or relating to any combination,
machine, or process in which such semiconductor devices might be or are used.
G-LINK Technology's products are not authorized for use in life support devices or systems. Life support devices or systems are device or systems which are: a) intended for
surgical implant into the human body and b) designed to support or sustain life; and when properly used according to label instructions, can reasonably be expected to cause
significant injury to the user in the event of failure.
The information contained in this document is believed to be entirely accurate. However, G-LINK Technology assumes no responsibility for inaccuracies.
www.glinktech.com
G-LINK Technology
2701 Northwestern Parkway
Santa Clara, CA 95051, USA
TEL: 408-492-9068 · FAX: 408-492-9067
G-LINK Technology Corporation, Taiwan
6F, No. 24-2, Industry E. Rd. IV
Science-Based Industrial Park
Hsin Chu, Taiwan, R.O.C.
TEL: 03-578-2833 · FAX: 03-578-5820
Printed in USA