  1. Apr 1, 2024 · K2CU-F80A-EGS. AC220V. 形K2CU-F10A-FGS. 形K2CU-F20A-FGS. 形K2CU-F40A-FGS. 形K2CU-F80A-FGS. 注. ヒータの温度コントロールにPID制御方式の温度調節器と組み合せて使用される場合は、ゲート入力端子つきタイプが必要です。. この場合の温度調節器は電圧出力タイプをご使用 ...

  2. Sep 24, 2012 · K2CU-F80A-EGS. 220 VAC. K2CU-F10A-FGS. K2CU-F20A-FGS. K2CU-F40A-FGS. K2CU-F80A-FGS. Note: A model with a gate input terminal is required to combine the K2CU with a temperature controller that uses PID. control for temperature control of a heater. To do so, use a temperature controller with a voltage output.

  3. People also ask

    • Accurate Detection of Heater Element Burnout Regardless of Heater Capacities
    • K2CU-F A- GS Series
    • K2CU-F Series
    • K2CU-F A- GS
    • K2CU-F

    Accurately detects a burned heater element or elements incorporated by a molding machine or packing machine and outputs an alarm signal. Precisely singles out the burned element even if one heater element among several heater elements has been burned out. Applicable to small- to large-capacity heater elements. All K2CU-F large-capacity, built-in cu...

    When power is supplied to the heater (when the SSR is ON), a cur-rent flows through the wires to the heater elements. At the same time, a voltage is imposed on the gate circuit and the K2CU-F A GS begins monitoring the current flowing through the heater wires. The current flowing to the heater wires is detected by the detector sections through each...

    When power is supplied to the heater (when the contactor is ON), a current flows through the wires to the heater elements. At the same time, a voltage is imposed on the power circuit of the K2CU-F. The current flowing to the heater wires is detected by the detector sections through each Current Transformer (CT) incorporated by the K2CU-F. The curre...

    The operation of the heater burnout detector can be easily checked as follows:

    When a single-phase heater is used, pass the two lines through the openings of the heater burnout detector. When a three-phase heat-er is used, pass two (phases) of the three lines through the open-ings. In either case, if only one line passes through, an alarm signal will always be produced. With power single-phase Heater Pass the lines through th...

    • 451KB
    • 14
  4. K2CU-F20A-DGS – Heater Element Detector 110VAC Chassis Mount from Omron Automation and Safety. Pricing and Availability on millions of electronic components from Digi-Key Electronics. Login or REGISTER Hello, {0} Account & Lists

    • Omron Automation And Safety
    • K2CU-F20A-DGS-ND
    • DETECT HEATER ELEMENT 110V CHAS
    • Omron Automation and Safety
  5. The control power source for the K2CU (except for the K2CU-F@@A-@GS) must be supplied from the load side via a contactor. Be sure to impose a voltage between the 0-V terminal and 100-V (or 110-V) terminal or the 0-V terminal and 200-V (or 220-V) terminal of the K2CU-P, otherwise the K2CU-P will not operate. & A.

  6. 110 VAC compensation K2CU-F10A-DGS K2CU-F20A-DGS K2CU-F40A-DGS K2CU-F80A-DGS 200 VAC K2CU-F10A-EGS K2CU-F20A-EGS K2CU-F40A-EGS K2CU-F80A-EGS 220 VAC K2CU-F10A-FGS K2CU-F20A-FGS K2CU-F40A-FGS K2CU-F80A-FGS K2CU-F Large-capacity, Built-in Current Transformer Models Control supply voltage Operating current 4 to 10 A 8 to 20 A 16 to 40 A 32 to 80 A ...

  7. 2. Y: External relay for self-holding circuit BZ: Alarm buzzer Alarm indicator 3. To use an 100 (110) VAC control power supply with K2CU-P, connect it to terminal 7 instead of 6. Precautions K2CU-F A- GS Pass the lines through the openings only once. Page 13 No. of heater per phase = n Note: 1.