ChipFind - Datasheet

Part Number CD54AC257

Download:  PDF   ZIP
CAUTION: These devices are sensitive to electrostatic discharge. Users should follow proper I.C. Handling Procedures.
Copyright
©
Harris Corporation 1994
1
S E M I C O N D U C T O R
CD54AC257/3A
CD54ACT257/3A
Quad 2-Input Multiplexer
Three-State, Non-Inverting
Functional Diagram
2
5
11
14
6
13
10
3
4
7
12
9
4Y
3Y
2Y
1Y
1I
0
2I
0
3I
0
4I
0
1I
1
2I
1
3I
1
4I
1
S
OE
1
15
Description
The CD54AC257/3A and CD54ACT257/3A are quad 2-input
multiplexers with three-state outputs. These devices utilize
the Harris Advanced CMOS Logic technology. Each of these
devices selects four bits of data from two sources under the
control of a common Select input (S). The Output Enable
(OE) is active LOW. When OE is HIGH, all of the outputs (Y)
are in the high-impedance state regardless of all other input
conditions.
Moving data from two groups of registers to four common
output buses is a common use of the CD54AC/ACT257/3A.
The state of the Select input determines the particular regis-
ter from which the data comes. The CD54AC/ACT257/3A
can also be used as function generators.
The CD54AC257/3A and CD54ACT257/3A are supplied in
16 lead dual-in-line ceramic packages (F suffix).
ACT INPUT LOAD TABLE
INPUT
UNIT LOAD (NOTE 1)
Data
0.83
S
1.27
OE
1.27
NOTE:
1. Unit load is
I
CC
limit specified in DC Electrical Specifications
Table, e.g., 2.4mA Max at +25
o
C.
June 1997
File Number
3903
Absolute Maximum Ratings
DC Supply Voltage, V
CC
. . . . . . . . . . . . . . . . . . . . . . . . -0.5V to +6V
DC Input Diode Current, I
IK
For V
I
< -0.5V or V
I
> V
CC
+ 0.5V
. . . . . . . . . . . . . . . . . . . . . .±
20mA
DC Output Diode Current, I
OK
For V
O
< -0.5V or V
O
> V
CC
+ 0.5V
. . . . . . . . . . . . . . . . . . . . .±
50mA
DC Output Source or Sink Current, Per Output Pin, I
O
For V
O
> -0.5V or V
O
< V
CC
+ 0.5V
. . . . . . . . . . . . . . . . . . . . .±
50mA
DC V
CC
or GND Current, I
CC
or I
GND
For Up to 4 Outputs Per Device, Add
±
25mA For Each
Additional Output
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .±
100mA
Power Dissipation Per Package, P
D
T
A
= -55
o
C to +100
o
C (Package F) . . . . . . . . . . . . . . . . . . 500mW
T
A
= +100
o
C to +125
o
C (Package F) . . . . . . . . Derate Linearly at
8mW/
o
C to 300mW
Operating Temperature Range, T
A
Package Type F . . . . . . . . . . . . . . . . . . . . . . . . . . -55
o
C to +125
o
C
Storage Temperature, T
STG
. . . . . . . . . . . . . . . . . . -65
o
C to +150
o
C
Lead Temperature (During Soldering)
At Distance 1/16in.
±
1/32in. (1.59mm
±
0.79mm)
From Case For 10s Max . . . . . . . . . . . . . . . . . . . . . . . . . . +265
o
C
Unit Inserted Into a PC Board (Min Thickness 1/16in., 1.59mm)
With Solder Contacting Lead Tips Only. . . . . . . . . . . . . . . +300
o
C
CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only rating and operation
of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Recommended Operating Conditions
Supply Voltage Range, V
CC
Unless Otherwise Specified, All Voltages Referenced to GND
T
A
= Full Package Temperature Range
CD54AC Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.5V to 5.5V
CD54ACT Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.5V to 5.5V
DC Input or Output Voltage, V
I
, V
O
. . . . . . . . . . . . . . . . . . 0V to V
CC
Operating Temperature, T
A
. . . . . . . . . . . . . . . . . . . -55
o
C to +125
o
C
Input Rise and Fall Slew Rate, dt/dv
at 1.5V to 3V (AC Types) . . . . . . . . . . . . . . . . . . . 0ns/V to 50ns/V
at 3.6V to 5.5V (AC Types) . . . . . . . . . . . . . . . . . 0ns/V to 20ns/V
at 4.5V to 5.5V (AC Types) . . . . . . . . . . . . . . . . . 0ns/V to 10ns/V
COMING SOON!
COMPLETE DATA SHEET