Part Number DM74LS136

Download:  PDF   ZIP
© 2000 Fairchild Semiconductor Corporation
DS009819
www.fairchildsemi.com
October 1988
Revised March 2000
DM74LS136

Quad 2-I
nput Excl
usive
-OR
Gat
e

wi
th O
p
en-Col
l
ect
or Output
s
DM74LS136
Quad 2-Input Exclusive-OR Gate with
Open-Collector Outputs
General Description
This device contains four independent gates, each of which
performs the logic exclusive-OR function.
Ordering Code:
Devices also available in Tape and Reel. Specify by appending the suffix letter "X" to the ordering code.
Connection Diagram
Truth Table
H
=
HIGH Voltage Level
L
=
LOW Voltage Level
Order Number
Package Number
Package Description
DM74LS136M
M14A
14-Lead Small Outline Integrated Circuit (SOIC), JEDEC MS-120, 0.150 Narrow
DM74LS136N
N14A
14-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300 Wide
Inputs
Output
A
B
Z
L
L
L
L
H
H
H
L
H
H
H
L
www.fairchildsemi.com
2
DM74LS136
Absolute Maximum Ratings
(Note 1)
Note 1: The "Absolute Maximum Ratings" are those values beyond which
the safety of the device cannot be guaranteed. The device should not be
operated at these limits. The parametric values defined in the Electrical
Characteristics tables are not guaranteed at the absolute maximum ratings.
The "Recommended Operating Conditions" table will define the conditions
for actual device operation.
Recommended Operating Conditions
Electrical Characteristics
Over recommended operating free air temperature range (unless otherwise noted)
Note 2: All typicals are at V
CC
=
5V, T
A
=
25
°
C.
Note 3: Not more than one output should be shorted at a time, and the duration should not exceed one second.
Switching Characteristics
at V
CC
=
5V and T
A
=
25
°
C
Supply Voltage
7V
Input Voltage
7V
Operating Free Air Temperature Range
0
°
C to
+
70
°
C
Storage Temperature Range
-
65
°
C to
+
150
°
C
Symbol
Parameter
Min
Nom
Max
Units
V
CC
Supply Voltage
4.75
5
5.25
V
V
IH
HIGH Level Input Voltage
2
V
V
IL
LOW Level Input Voltage
0.8
V
I
OL
LOW Level Output Current
8
mA
T
A
Free Air Operating Temperature
0
70
°
C
Symbol
Parameter
Conditions
Min
Typ
Max
Units
(Note 2)
V
I
Input Clamp Voltage
V
CC
=
Min, I
I
=
-
18 mA
-
1.5
V
I
CEX
HIGH Level Output Current
V
CC
=
Min, V
O
=
5.5V
100
µ
A
V
OL
LOW Level
V
CC
=
Min, I
OL
=
Max
0.35
0.5
Output Voltage
V
IH
=
Min
V
I
OL
=
4 mA, V
CC
=
Min
0.25
0.4
I
I
Input Current @ Max Input Voltage
V
CC
=
Max, V
I
=
7V
0.2
mA
I
IH
HIGH Level Input Current
V
CC
=
Max, V
I
=
2.7V
40
µ
A
I
IL
LOW Level Input Current
V
CC
=
Max, V
I
=
0.4V
-
0.6
mA
I
CC
Supply Current
V
CC
=
Max
10
mA
R
L
=
2 k
Symbol
Parameter
C
L
=
15 pF
Units
Min
Max
t
PLH
Propagation Delay Time
23
ns
LOW-to-HIGH Level Output
t
PHL
Propagation Delay Time
23
ns
HIGH-to-LOW Level Output
3
www.fairchildsemi.com
DM74LS136
Physical Dimensions
inches (millimeters) unless otherwise noted
14-Lead Small Outline Integrated Circuit (SOIC), JEDEC MS-120, 0.150 Narrow
Package Number M14A
www.fairchildsemi.com
4
DM74LS136 Q
u
a
d

2-
Input
E
x
clusi
ve-
O
R
Gate wit
h

Open-
Coll
ect
or O
u
t
puts
Physical Dimensions
inches (millimeters) unless otherwise noted (Continued)
14-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300 Wide
Package Number N14A
Fairchild does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and
Fairchild reserves the right at any time without notice to change said circuitry and specifications.
LIFE SUPPORT POLICY
FAIRCHILD'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD
SEMICONDUCTOR CORPORATION. As used herein:
1. Life support devices or systems are devices or systems
which, (a) are intended for surgical implant into the
body, or (b) support or sustain life, and (c) whose failure
to perform when properly used in accordance with
instructions for use provided in the labeling, can be rea-
sonably expected to result in a significant injury to the
user.
2. A critical component in any component of a life support
device or system whose failure to perform can be rea-
sonably expected to cause the failure of the life support
device or system, or to affect its safety or effectiveness.
www.fairchildsemi.com