ChipFind - Datasheet

Part Number MC-4R128FKK6K

Download:  PDF   ZIP

Document Outline

Document No. E0269N10 (Ver. 1.0)
Date Published April 2002 (K) Japan
URL: http://www.elpida.com
Elpida Memory, Inc. 2002
Elpida Memory, Inc. is a joint venture DRAM company of NEC Corporation and Hitachi, Ltd.
PRELIMINARY DATA SHEET
128MB 32-bit Direct Rambus DRAM RIMM
Module
MC-4R128FKK6K (32M words
×
×
×
×
16 bits
×
×
×
×
2 channels)
Description
The 32-bit Direct Rambus RIMM module is a general-
purpose high-performance lines of memory modules
suitable for use in a broad range of applications
including computer memory, personal computers,
workstations, and other applications where high
bandwidth and latency are required.
The 32-bit RIMM module consists of 288Mb Direct
Rambus DRAM (Direct RDRAM) devices. These are
extremely high-speed CMOS DRAMs organized as
16M words by 18 bits. The use of Rambus Signaling
Level (RSL) technology permits the use of conventional
system and board design technologies. The 32-bit
RIMM modules support 800MHz transfer rate per pin,
resulting in total module bandwidth of 3.2GB/s.
The 32-bit RIMM module provides two independent 16
bit memory channels to facilitate compact system
design. The "Thru" Channel enters and exits the
module to support a connection to or from a controller,
memory slot, or termination. The "Term" Channel is
terminated on the module and supports a connection
from a controller or another memory slot.
The RDRAM
architecture enables the highest
sustained bandwidth for multiple, simultaneous,
randomly addressed memory transactions. The
separate control and data buses with independent row
and column control yield over 95% bus efficiency. The
RDRAM device multi-bank architecture supports up to
four simultaneous transactions per device.
Features
·
128MB Direct RDRAM storage and 128 banks total
on module
·
2 independent Direct RDRAM channels, 1 pass
through and 1 terminated on 32-bit RIMM module
·
High speed 800MHz Direct RDRAM devices
·
232 edge connector pads with 1mm pad spacing
Module PCB size: 133.35mm
×
39.925mm
×
1.27mm
Gold plated edge connector pads contacts
·
Serial Presence Detect (SPD) support
·
Operates from a 2.5V (
±
5%) supply
·
Low power and power down self refresh modes
·
Separate Row and Column buses for higher
efficiency
MC-4R128FKK6K
Preliminary Data Sheet E0269N10 (Ver. 1.0)
2
Ordering Information

Part number

Organization
I/O Freq.
(MHz)
RAS access
time (ns)

Package

Mounted devices
MC-4R128FKK6K-840
32M x 16 x 2
800
40
232 edge connector pads
RIMM with heat spreader
Edge connector: Gold plated
4 pieces of
µ
PD488588FF
FBGA (
µ
BGA
) package
Module Pad Names
Pad Signal name
Pad Signal name
Pad
Signal name
Pad
Signal name
A1
GND
B1
GND
A59
GND
B59
GND
A2
SCK_THRU_L
B2
CMD_THRU_L
A60
VTERM
B60
VTERM
A3
GND
B3
GND
A61
VTERM
B61
VTERM
A4
DQA8_THRU_L
B4
DQA7_THRU_L
A62
GND
B62
GND
A5
GND
B5
GND
A63
DQA3_THRU_R
B63
DQA4_THRU_R
A6
DQA6_THRU_L
B6
DQA5_THRU_L
A64
GND
B64
GND
A7
GND
B7
GND
A65
DQA5_THRU_R
B65
DQA6_THRU_R
A8
DQA4_THRU_L
B8
DQA3_THRU_L
A66
GND
B66
GND
A9
GND
B9
GND
A67
DQA7_THRU_R
B67
DQA8_THRU_R
A10 DQA2_THRU_L
B10 DQA1_THRU_L
A68
GND
B68
GND
A11 GND
B11 GND
A69
VDD
B69
VDD
A12 DQA0_THRU_L
B12 CTMN_THRU_L
A70
GND
B70
GND
A13 GND
B13 GND
A71
SCK_THRU_R
B71
CTMN_TERM_L
A14 CFM_THRU_L
B14 CTM_THRU_L
A72
GND
B72
GND
A15 GND
B15 GND
A73
CMD_THRU_R
B73
CTM_TERM_L
A16 CFMN_THRU_L
B16 ROW2_THRU_L
A74
GND
B74
GND
A17 GND
B17 GND
A75
VREF
B75
VCMOS
A18 ROW1_THRU_L
B18 ROW0_THRU_L
A76
VDD
B76
VDD
A19 GND
B19 GND
A77
SVDD
B77
SWP
A20 COL4_THRU_L
B20 COL3_THRU_L
A78
VDD
B78
VDD
A21 GND
B21 GND
A79
SCL
B79
SDA
A22 COL2_THRU_L
B22 COL1_THRU_L
A80
VDD
B80
VDD
A23 GND
B23 GND
A81
SA0
B81
SA1
A24 COL0_THRU_L
B24 DQB0_THRU_L
A82
VDD
B82
VDD
A25 GND
B25 GND
A83
SA2
B83
SIN_TERM
A26 DQB1_THRU_L
B26 DQB2_THRU_L
A84
GND
B84
GND
A27 GND
B27 GND
A85
DQB8_TERM
B85
DQB7_TERM
A28 DQB3_THRU_L
B28 DQB4_THRU_L
A86
GND
B86
GND
A29 GND
B29 GND
A87
DQB6_TERM
B87
DQB5_TERM
A30 DQB5_THRU_L
B30 DQB6_THRU_L
A88
GND
B88
GND
A31 GND
B31 GND
A89
DQB4_TERM
B89
DQB3_TERM
A32 DQB7_THRU_L
B32 DQB8_THRU_L
A90
GND
B90
GND
A33 GND
B33 GND
A91
DQB2_TERM
B91
DQB1_TERM
A34 SOUT_THRU
B34 SIN_THRU
A92
GND
B92
GND
A35 GND
B35 GND
A93
DQB0_TERM
B93
COL0_TERM
A36 DQB8_THRU_R
B36 DQB7_THRU_R
A94
GND
B94
GND
MC-4R128FKK6K
Preliminary Data Sheet E0269N10 (Ver. 1.0)
3
Pad Signal name
Pad Signal name
Pad
Signal name
Pad
Signal name
A37 GND
B37 GND
A95
COL1_TERM
B95
COL2_TERM
A38 DQB6_THRU_R
B38 DQB5_THRU_R
A96
GND
B96
GND
A39 GND
B39 GND
A97
COL3_TERM
B97
COL4_TERM
A40 DQB4_THRU_R
B40 DQB3_THRU_R
A98
GND
B98
GND
A41 GND
B41 GND
A99
ROW0_TERM
B99
ROW1_TERM
A42 DQB2_THRU_R
B42 DQB1_THRU_R
A100
GND
B100
GND
A43 GND
B43 GND
A101
ROW2_TERM
B101
CFMN_TERM
A44 DQB0_THRU_R
B44 COL0_THRU_R
A102
GND
B102
GND
A45 GND
B45 GND
A103
CTM_TERM_R
B103
CFM_TERM
A46 COL1_THRU_R
B46 COL2_THRU_R
A104
GND
B104
GND
A47 GND
B47 GND
A105
CTMN_TERM_R
B105
DQA0_TERM
A48 COL3_THRU_R
B48 COL4_THRU_R
A106
GND
B106
GND
A49 GND
B49 GND
A107
DQA1_TERM
B107
DQA2_TERM
A50 ROW0_THRU_R
B50 ROW1_THRU_R
A108
GND
B108
GND
A51 GND
B51 GND
A109
DQA3_TERM
B109
DQA4_TERM
A52 ROW2_THRU_R
B52 CFMN_THRU_R
A110
GND
B110
GND
A53 GND
B53 GND
A111
DQA5_TERM
B111
DQA6_TERM
A54 CTM_THRU_R
B54 CFM_THRU_R
A112
GND
B112
GND
A55 GND
B55 GND
A113
DQA7_TERM
B113
DQA8_TERM
A56 CTMN_THRU_R
B56 DQA0_THRU_R
A114
GND
B114
GND
A57 GND
B57 GND
A115
CMD_TERM
B115
SCK_TERM
A58 DQA1_THRU_R
B58 DQA2_THRU_R
A116
GND
B116
GND
MC-4R128FKK6K
Preliminary Data Sheet E0269N10 (Ver. 1.0)
4
Module Connector Pad Description

Signal
Module
connector pads

I/O

Type

Description
CFM_THRU_L
A14
I
RSL
Clock From Master. Connects to left RDRAM device on
"Thru" Channel. Interface clock used for receiving RSL
signals from the controller. Positive polarity.
CFM_THRU_R
B54
I
RSL
Clock From Master. Connects to right RDRAM device on
"Thru" Channel. Interface clock used for receiving RSL
signals from the controller. Positive polarity.
CFMN_THRU_L
A16
I
RSL
Clock From Master. Connects to left RDRAM device on
"Thru" Channel. Interface clock used for receiving RSL
signals from the controller. Negative polarity.
CFMN_THRU_R
B52
I
RSL
Clock From Master. Connects to right RDRAM device on
"Thru" Channel. Interface clock used for receiving RSL
signals from the controller. Negative polarity.
CMD_THRU_L
B2
I
VCMOS
Serial Command Input used to read from and write to the
control registers. Also used for power management.
Connects to left RDRAM device on "Thru" Channel.
CMD_THRU_R
A73
I
VCMOS
Serial Command Input used to read from and write to the
control registers. Also used for power management.
Connects to right RDRAM device on "Thru" Channel.
COL4_THRU_L..
COL0_THRU_L
A20, B20, A22, B22,
A24
I
RSL
"Thru" Channel Column bus. 5-bit bus containing control and
address information for column accesses. Connects to left
RDRAM device on "Thru" Channel.
COL4_THRU_R..
COL0_THRU_R
B48, A48, B46, A46,
B44
I
RSL
"Thru" Channel Column bus. 5-bit bus containing control and
address information for column accesses. Connects to right
RDRAM device on "Thru" Channel.
CTM_THRU_L
B14
I
RSL
Clock To Master. Connects to left RDRAM device on "Thru"
Channel. Interface clock used for transmitting RSL signals to
the controller. Positive polarity.
CTM_THRU_R
A54
I
RSL
Clock To Master. Connects to right RDRAM device on "Thru"
Channel. Interface clock used for transmitting RSL signals to
the controller. Positive polarity.
CTMN_THRU_L
B12
I
RSL
Clock To Master. Connects to left RDRAM device on "Thru"
Channel. Interface clock used for transmitting RSL signals to
the controller. Negative polarity.
CTMN_THRU_R
A56
I
RSL
Clock To Master. Connects to right RDRAM device on "Thru"
Channel. Interface clock used for transmitting RSL signals to
the controller. Negative polarity.
DQA8_THRU_L..
DQA0_THRU_L
A4, B4, A6, B6, A8,
B8, A10, B10, A12
I/O
RSL
"Thru" Channel Data bus A. A 9-bit bus carrying a byte of
read or write data between the controller and RDRAM devices
on "Thru" Channel. Connects to left RDRAM device on "Thru"
Channel. DQA8_THRU_L is non-functional on modules.
DQA8_THRU_R..
DQA0_THRU_R
B67, A67, B65, A65,
B63, A63, B58, A58,
B56
I/O
RSL
"Thru" Channel Data bus A. A 9-bit bus carrying a byte of
read or write data between the controller and RDRAM devices
on "Thru" Channel. Connects to right RDRAM device on
"Thru" Channel. DQA8_THRU_R is non-functional on
modules.
DQB8_THRU_L..
DQB0_THRU_L
B32, A32, B30, A30,
B28, A28, B26, A26,
B24
I/O
RSL
"Thru" Channel Data bus B. A 9-bit bus carrying a byte of
read or write data between the controller and RDRAM devices
on "Thru" Channel. Connects to left RDRAM device on "Thru"
Channel. DQB8_THRU_L is non-functional on modules.
DQB8_THRU_R..
DQB0_THRU_R
A36, B36, A38, B38,
A40, B40, A42, B42,
A44
I/O
RSL
"Thru" Channel Data bus B. A 9-bit bus carrying a byte of
read or write data between the controller and RDRAM devices
on "Thru" Channel. Connects to right RDRAM device on
"Thru" Channel. DQB8_THRU_R is non-functional on
modules.
ROW2_THRU_L..
ROW0_THRU_L
B16, A18, B18
I
RSL
Row bus. 3-bit bus containing control and address information
for row accesses. Connects to left RDRAM device on "Thru"
Channel.
MC-4R128FKK6K
Preliminary Data Sheet E0269N10 (Ver. 1.0)
5

Signal
Module
connector pads

I/O

Type

Description
ROW2_THRU_R..
ROW0_THRU_R
A52, B50, A50
I
RSL
Row bus. 3-bit bus containing control and address information
for row accesses. Connects to right RDRAM device on "Thru"
Channel.
SCK_THRU_L
A2
I
VCMOS
Serial Clock input. Clock source used to read from and write
to "Thru" Channel RDRAM control registers. Connects to left
RDRAM device on "Thru" Channel.
SCK_THRU_R
A71
I
VCMOS
Serial Clock input. Clock source used to read from and write
to "Thru" Channel RDRAM control registers. Connects to right
RDRAM device on "Thru" Channel.
SIN_THRU
B34
I/O
VCMOS
"Thru" Channel Serial I/O for reading from and writing to the
control registers. Attaches to SIO0 of right RDRAM device on
"Thru" Channel.
SOUT_THRU
A34
I/O
VCMOS
"Thru" Channel Serial I/O for reading from and writing to the
control registers. Attaches to SIO1 of left RDRAM device on
"Thru" Channel.
CFM_TERM
B103
I
RSL
Clock from master. Connects to right RDRAM device on
"Term" Channel. Interface clock used for receiving RSL
signals from the controller. Positive polarity.
CFMN_TERM
B101
I
RSL
Clock from master. Connects to right RDRAM device on
"Term" Channel. Interface clock used for receiving RSL
signals from the controller. Negative polarity.
CMD_TERM
A115
I
VCMOS
Serial Command Input used to read from and write to the
control registers. Also used for power management.
Connects to right RDRAM device on "Term" Channel.
COL4_TERM..
COL0_TERM
B97, A97, B95, A95,
B93
I
RSL
"Term" Channel Column bus. 5-bit bus containing control and
address information for column accesses. Connects to right
RDRAM device on "Term" Channel.
CTM_TERM_L
B73
I
RSL
Clock To Master. Connects to left RDRAM device on "Term"
Channel. Interface clock used for transmitting RSL signals to
the controller. Positive polarity.
CTM_TERM_R
A103
I
RSL
Clock To Master. Connects to right RDRAM device on "Term"
Channel. Interface clock used for transmitting RSL signals to
the controller. Positive polarity.
CTMN_TERM_L
B71
I
RSL
Clock To Master. Connects to left RDRAM device on "Term"
Channel. Interface clock used for transmitting RSL signals to
the controller. Negative polarity.
CTMN_TERM_R
A105
I
RSL
Clock To Master. Connects to right RDRAM device on "Term"
Channel. Interface clock used for transmitting RSL signals to
the controller. Negative polarity.
DQA8_TERM..
DQA0_TERM
B113, A113, B111,
A111, B109, A109,
B107, A107, B105
I/O
RSL
"Term" Channel Data bus A. A 9-bit bus carrying a byte of
read or write data between the controller and RDRAM devices
on "Term" Channel. Connects to right RDRAM device on
"Term" Channel. DQA8_TERM is non-functional on modules.
DQB8_TERM..
DQB0_TERM
A85, B85, A87, B87,
A89, B89, A91, B91,
A93
I/O
RSL
"Term" Channel Data bus B. A 9-bit bus carrying a byte of
read or write data between the controller and RDRAM devices
on "Term" Channel. Connects to right RDRAM device on
"Term" Channel. DQB8_TERM is non-functional on modules.
ROW2_TERM..
ROW0_TERM
A101, B99, A99
I
RSL
"Term" Channel Row bus. 3-bit bus containing control and
address information for row accesses. Connects to right
RDRAM device on "Term" Channel.
SCK_TERM
B115
I
VCMOS
Serial Clock input. Clock source used to read from and write
to "Term" Channel RDRAM control registers. Connects to
right RDRAM device on "Term" Channel.
SIN_TERM
B83
I/O
VCMOS
"Term" Channel Serial I/O for reading from and writing to the
control registers. Attaches to SIO0 of left RDRAM device on
"Term" Channel.
VTERM
A60, B60, A61, B61
"Term" Channel Termination voltage.