ChipFind - Datasheet

Part Number MDU14

Download:  PDF   ZIP
MDU14
Doc #97042
DATA DELAY DEVICES, INC.
1
12/15/97
3 Mt. Prospect Ave. Clifton, NJ 07013
QUAD, ECL-INTERFACED
FIXED DELAY LINE
(SERIES MDU14)
FEATURES
PACKAGES
·
Four independent delay lines
·
Fits 24-pin (400mil) DIP socket
·
Auto-insertable
·
Input & outputs fully 100K-ECL interfaced & buffered
FUNCTIONAL DESCRIPTION
The MDU14-series device is a 4-in-1 digitally buffered delay line. The
signal inputs (I1-I4) are reproduced at the outputs (O1-O4), shifted in time
by an amount determined by the device dash number (See Table). The
delay lines function completely independently of each other.
SERIES SPECIFICATIONS
·
Minimum input pulse width: 40% of total delay
·
Output rise time: 2ns typical
·
Supply voltage: -5VDC
±
5%
·
Power dissipation: 500mw typical (no load)
·
Operating temperature: 0
°
to 85
°
C
·
Temp. coefficient of total delay: 100 PPM/
°
C
100%
VCC
GND
I1
I2
I3
Functional block diagram
100%
100%
O3
O2
O1
I4
100%
O4
©
©
1997 Data Delay Devices
data
delay
devices,
inc.
®
®
3
24
22
20
19
18
16
13
1
3
5
6
7
9
11
GND
O1
O2
GND
GND
O3
O4
I1
I2
I3
GND
VEE
I4
GND
1
2
3
4
5
6
7
8
9
10
11
12
24
23
22
21
20
19
18
17
16
15
14
13
GND
N/C
O1
N/C
O2
GND
GND
N/C
O3
N/C
O4
N/C
I1
N/C
I2
N/C
I3
GND
VEE
N/C
I4
N/C
N/C
GND
MDU14-xx
DIP
MDU14-xxM
Military DIP
DDU14-xxC4
SMD
DDU14-xxMC4
Mil SMD
PIN DESCRIPTIONS
I1-I4
Signal Inputs
O1-O4 Signal Outputs
VEE
-5 Volts
GND
Ground
DASH NUMBER SPECIFICATIONS
Part
Number
Total
Delay (ns)
MDU14-2
2.0
±
1.0
MDU14-2.5
2.5
±
1.0
MDU14-3
3.0
±
1.0
MDU14-4
4.0
±
1.0
MDU14-5
5.0
±
1.0
MDU14-6
6.0
±
1.0
MDU14-7
7.0
±
1.0
MDU14-8
8.0
±
1.0
MDU14-9
9.0
±
1.0
MDU14-10
10.0
±
1.0
MDU14-12.5
12.5
±
1.0
MDU14-15
15.0
±
1.0
MDU14-20
20.0
±
1.0
MDU14-25
25.0
±
1.2
NOTE: Any dash number between 2 and 25
not shown is also available.
MDU14
Doc #97042
DATA DELAY DEVICES, INC.
2
12/15/97
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
APPLICATION NOTES
HIGH FREQUENCY RESPONSE
The MDU14 tolerances are guaranteed for input
pulse widths and periods greater than those
specified in the test conditions. Although the
device will function properly for pulse widths as
small as 40% of the total delay and periods as
small as 80% of the total delay (for a symmetric
input), the delays may deviate from their values at
low frequency. However, for a given input
condition, the deviation will be repeatable from
pulse to pulse. Contact technical support at Data
Delay Devices if your application requires device
testing at a specific input condition.
POWER SUPPLY BYPASSING
The MDU14 relies on a stable power supply to
produce repeatable delays within the stated
tolerances. A 0.1uf capacitor from VEE to GND,
located as close as possible to the VEE pin, is
recommended. A wide VEE trace and a clean
ground plane should be used.
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
MIN
MAX
UNITS
NOTES
DC Supply Voltage
V
EE
-7.0
0.3
V
Input Pin Voltage
V
IN
V
EE
- 0.3
0.3
V
Storage Temperature
T
STRG
-55
150
C
Lead Temperature
T
LEAD
300
C
10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
(0C to 85C)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
High Level Output Voltage
V
OH
-1.025
-0.880
V
V
IH
= MAX,50
to -2V
Low Level Output Voltage
V
OL
-1.810
-1.620
V
V
IL
= MIN, 50
to -2V
High Level Input Voltage
V
IH
-1.165
-0.880
V
Low Level Input Voltage
V
IL
-1.810
-1.475
V
High Level Input Current
I
IH
340
µ
A
V
IH
= MAX
Low Level Input Current
I
IL
0.5
µ
A
V
IL
= MIN
MDU14
Doc #97042
DATA DELAY DEVICES, INC.
3
12/15/97
3 Mt. Prospect Ave. Clifton, NJ 07013
PACKAGE DIMENSIONS
19
18
20
22
MDU14-xx (Commercial DIP)
MDU14-xxM (Military DIP)
.130
±
.030
1.300 MAX.
1
6
.300
MAX.
.018 TYP.
.530
MAX.
.400
TYP.
.012 TYP.
1.100 TYP.
.015
TYP.
.100 TYP.
11
13
24
5
3
7
9
16
MDU14-xxC4 (Commercial SMD)
MDU14-xxMC4 (Military SMD)
1.280
±
.020
.882
±
.005
.020 TYP.
.040 TYP.
.100
.090
1.100
.280
MAX.
.590
MAX.
.010
±
.002
.050
±
.010
.710
±
.005
.007
±
.005
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
MDU14
Doc #97042
DATA DELAY DEVICES, INC.
4
12/15/97
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
DELAY LINE AUTOMATED TESTING
TEST CONDITIONS
INPUT:
OUTPUT:
Ambient Temperature: 25
o
C
±
3
o
C
Load:
50
to -2V
Supply Voltage (Vcc): -5.0V
±
0.1V
C
load
:
5pf
±
10%
Input Pulse:
Standard 10KH ECL
Threshold: (V
OH
+ V
OL
) / 2
levels
(Rising & Falling)
Source Impedance:
50
Max.
Rise/Fall Time:
2.0 ns Max. (measured
between 20% and 80%)
Pulse Width:
PW
IN
= 1.5 x Total Delay
Period:
PER
IN
= 10 x Total Delay
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
O1
TRIG
IN
REF
Test Setup
DEVICE UNDER
TEST (DUT)
OSCILLOSCOPE
PULSE
GENERATOR
O2
O3
OUT
TRIG
I1
I2
I3
O4
I4
Timing Diagram For Testing
T
RISE
T
FALL
PER
IN
PW
IN
T
RISE
T
FALL
20%
20%
50%
50%
80%
80%
50%
50%
V
IH
V
IL
V
OH
V
OL
INPUT
SIGNAL