3 Mt. Prospect Ave. Clifton, NJ 07013
TRIPLE, ECL-INTERFACED
FIXED DELAY LINE
(SERIES MDU13H)
FEATURES
PACKAGES
·
Three independent delay lines
·
Fits standard 16-pin DIP socket
·
Auto-insertable
·
Input & outputs fully 10KH-ECL interfaced & buffered
FUNCTIONAL DESCRIPTION
The MDU13H-series device is a 3-in-1 digitally buffered delay line. The
signal inputs (I1-I3) are reproduced at the outputs (O1-O3), shifted in time
by an amount determined by the device dash number (See Table). The
delay lines function completely independently of each other.
SERIES SPECIFICATIONS
·
Minimum input pulse width: 50% of total delay
·
Output rise time: 2ns typical
·
Supply voltage: -5VDC
±
5%
·
Power dissipation: 200mw typical (no load)
·
Operating temperature: -30
°
to 85
°
C
·
Temp. coefficient of total delay: 100 PPM/
°
C
100%
VCC
GND
I1
I2
I3
Functional block diagram
100%
100%
O3
O2
O1
©
©
1997 Data Delay Devices
data
delay
devices,
inc.
®
®
3
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
GND
N/C
N/C
N/C
I1
I2
I3
VEE
GND
O1
O2
O3
N/C
N/C
N/C
N/C
16
15
14
13
1
5
6
7
8
GND
I1
I2
I3
VEE
GND
O1
O2
O3
MDU13H-xx
DIP
MDU13H-xxM Military DIP
MDU13H-xxC3
SMD
MDU13H-xxMC3 Mil SMD
PIN DESCRIPTIONS
I1-I3
Signal Inputs
O1-O3 Signal Outputs
VEE
-5 Volts
GND
Ground
DASH NUMBER SPECIFICATIONS
Part
Number
Delay Per
Line (ns)
MDU13H-3
3
±
1.0
MDU13H-4
4
±
1.0
MDU13H-5
5
±
1.0
MDU13H-10
10
±
1.0
MDU13H-15
15
±
1.0
MDU13H-20
20
±
1.0
MDU13H-25
25
±
2.0
MDU13H-30
30
±
2.0
MDU13H-35
35
±
2.0
MDU13H-40
40
±
2.0
MDU13H-45
45
±
2.2
MDU13H-50
50
±
2.5
* Total delay is referenced to first tap output
Input to first tap = 1.5ns
±
±
1ns
NOTE: Any dash number between 3 and 50
not shown is also available.
MDU13H
Doc #97037
DATA DELAY DEVICES, INC.
2
12/11/97
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
APPLICATION NOTES
HIGH FREQUENCY RESPONSE
The MDU13H tolerances are guaranteed for
input pulse widths and periods greater than those
specified in the test conditions. Although the
device will function properly for pulse widths as
small as 50% of the total delay and periods as
small as 100% of the total delay (for a symmetric
input), the delays may deviate from their values
at low frequency. However, for a given input
condition, the deviation will be repeatable from
pulse to pulse. Contact technical support at Data
Delay Devices if your application requires device
testing at a specific input condition.
POWER SUPPLY BYPASSING
The MDU13H relies on a stable power supply to
produce repeatable delays within the stated
tolerances. A 0.1uf capacitor from VEE to GND,
located as close as possible to the VEE pin, is
recommended. A wide VEE trace and a clean
ground plane should be used.
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
MIN
MAX
UNITS
NOTES
DC Supply Voltage
V
EE
-7.0
0.3
V
Input Pin Voltage
V
IN
V
EE
- 0.3
0.3
V
Storage Temperature
T
STRG
-55
150
C
Lead Temperature
T
LEAD
300
C
10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
(0C to 75C)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
High Level Output Voltage
V
OH
-1.020
-0.735
V
V
IH
= MAX,50
to -2V
Low Level Output Voltage
V
OL
-1.950
-1.600
V
V
IL
= MIN, 50
to -2V
High Level Input Voltage
V
IH
-1.070
V
Low Level Input Voltage
V
IL
-1.480
V
High Level Input Current
I
IH
475
µ
A
V
IH
= MAX
Low Level Input Current
I
IL
0.5
µ
A
V
IL
= MIN
MDU13H
Doc #97037
DATA DELAY DEVICES, INC.
3
12/11/97
3 Mt. Prospect Ave. Clifton, NJ 07013
PACKAGE DIMENSIONS
MDU13H-xx (Commercial DIP)
MDU13H-xxM (Military DIP)
.150
±
.030
.800 TYP.
1
5
6
7
8
16
15
14
13
.320
MAX.
.018 TYP.
.400
TYP.
.300
TYP.
.010 TYP.
.700 TYP.
.020
TYP.
.100
TYP.
MDU13H-xxC3 (Commercial SMD)
MDU13H-xxMC3 (Military SMD)
.880
±
.020
.882
±
.005
.020 TYP.
.040
TYP.
.100
.090
.700
.280
MAX.
.590
MAX.
.010
±
.002
.050
±
.010
.710
±
.005
.007
±
.005
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MDU13H
Doc #97037
DATA DELAY DEVICES, INC.
4
12/11/97
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
DELAY LINE AUTOMATED TESTING
TEST CONDITIONS
INPUT:
OUTPUT:
Ambient Temperature: 25
o
C
±
3
o
C
Load:
50
to -2V
Supply Voltage (Vcc): -5.0V
±
0.1V
C
load
:
5pf
±
10%
Input Pulse:
Standard 10KH ECL
Threshold: (V
OH
+ V
OL
) / 2
levels
(Rising & Falling)
Source Impedance:
50
Max.
Rise/Fall Time:
2.0 ns Max. (measured
between 20% and 80%)
Pulse Width:
PW
IN
= 1.5 x Total Delay
Period:
PER
IN
= 10 x Total Delay
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
O1
TRIG
IN
REF
Test Setup
DEVICE UNDER
TEST (DUT)
OSCILLOSCOPE
PULSE
GENERATOR
O2
O3
OUT
TRIG
I1
I2
I3
Timing Diagram For Testing
T
RISE
T
FALL
PER
IN
PW
IN
T
RISE
T
FALL
20%
20%
50%
50%
80%
80%
50%
50%
V
IH
V
IL
V
OH
V
OL
INPUT
SIGNAL
OUTPUT