ChipFind - Datasheet

Part Number HCPL-7820

Download:  PDF   ZIP

Document Outline

1-233
5965-3591E
H
High CMR Analog Isolation
Amplifiers
Technical Data
Features
· Fast Propagation Delays for
Over-Current and Fault
Detection Sensing
· High Common Mode
Rejection (CMR): 30 kV/
µ
s at
V
CM
= 1000 V*
· 3% Gain Tolerance:
HCPL-7820
5% Gain Tolerance:
HCPL-7825
· 0.05% Nonlinearity
· Low Offset Voltage and Off-
set Drift vs. Temperature
· 200 kHz Bandwidth
· Performance Specified for
Common Motor Control
Applications over -40
°
C to
100
°
C Temperature Range
· Worldwide Safety and
Regulatory Approval: UL
1577 (3750 V rms/1 Min),
VDE 0884 and CSA
· Compact Auto-Insertable
Standard 8-Pin DIP Package
· Advanced Sigma-Delta (
)
A/D Converter Technology
· 1
µ
m CMOS IC Technology
Applications
· Motor Phase and Rail
Current Sensing
· General Purpose Current
Sensing and Monitoring
· High-Voltage Monitoring
· Switched Mode Power
Supply Signal Isolation
· General Purpose Analog
Signal Isolation
· Transducer Isolation
Description
The HCPL-7820/7825 high CMR
isolation amplifier consists of a
sigma-delta analog-to-digital
converter optically coupled to an
integrated output digital-to-analog
converter. When used with a
shunt resistor in the current path,
the HCPL-7820/7825 provides a
cost-effective, auto-insertion
compatible current sense solution.
Fast propagation delays allow this
part to be used in either motor
drive or inverter applications for
either phase current monitoring
or rail current fault detection
applications. High isolation mode
*The terms common-mode rejection (CMR) and isolation-mode rejection (IMR) are used interchangeably throughout this data sheet.
A 0.1
µ
F bypass capacitor must be connected between pins 1 and 4 and between pins 5 and 8.
rejection makes this product
suitable for noisy electrical
environments, such as those
generated by the high switching
rates of power IGBTs. Low offset
voltage together with low offset
change vs. temperature permits
accurate use of auto-calibration
techniques. Tight gain tolerance
with good nonlinearity further
provide the characteristics needed
to insure highly accurate motor
speed control. A high operating
temperature range with specified
performance parameters allow
HCPL-7820
HCPL-7825
CAUTION: It is advised that normal static precautions be taken in handling and assembly of this component to
prevent damage and/or degradation which may be induced by ESD.
Functional Diagram
1
IDD1
2
3
4
VDD1
VIN+
VIN­
GND1
8
IDD2
7
6
5
VDD2
VOUT+
VOUT­
GND2
+
­
+
­
CMR SHIELD
1-234
this device to be used in hostile
industrial environments. This
performance is delivered in an
auto-insertable, industry standard
Ordering Information
HCPL-782x
0 =
±
3% Gain Tolerance
5 =
±
5% Gain Tolerance
Option yyy
300 = Gull Wing Surface Mount Lead Option
500 = Tape/Reel Package Option (1 k min.)
Option datasheets available. Contact your Hewlett-Packard sales representative or authorized distributor for
information.
Package Outline Drawings
Standard DIP Package
9.40 (0.370)
9.90 (0.390)
PIN ONE
1.78 (0.070) MAX.
1.19 (0.047) MAX.
HP 7820
YYWW
DATE CODE
0.76 (0.030)
1.24 (0.049)
2.28 (0.090)
2.80 (0.110)
0.51 (0.020) MIN.
0.65 (0.025) MAX.
4.70 (0.185) MAX.
2.92 (0.115) MIN.
6.10 (0.240)
6.60 (0.260)
0.20 (0.008)
0.33 (0.013)
5° TYP.
7.36 (0.290)
7.88 (0.310)
DIMENSIONS IN MILLIMETERS AND (INCHES).
1
2
3
4
8
7
6
5
5
6
7
8
4
3
2
1
GND1
VDD1
VIN+
VIN­
GND2
VDD2
VOUT+
VOUT­
PIN DIAGRAM
PIN ONE
TYPE NUMBER
8-pin DIP package that meets
major worldwide regulatory and
safety approval ratings to help
ensure that your equipment can
be certified in many geographic
areas.
1-235
Gull Wing Surface Mount Option 300*
0.635 ± 0.25
(0.025 ± 0.010)
12° NOM.
0.20 (0.008)
0.33 (0.013)
9.65 ± 0.25
(0.380 ± 0.010)
0.51 ± 0.130
(0.020 ± 0.005)
7.62 ± 0.25
(0.300 ± 0.010)
5
6
7
8
4
3
2
1
9.65 ± 0.25
(0.380 ± 0.010)
6.350 ± 0.25
(0.250 ± 0.010)
1.02 (0.040)
1.19 (0.047)
1.19 (0.047)
1.78 (0.070)
9.65 ± 0.25
(0.380 ± 0.010)
4.83
(0.190)
TYP.
0.380 (0.015)
0.635 (0.025)
PIN LOCATION (FOR REFERENCE ONLY)
1.080 ± 0.320
(0.043 ± 0.013)
4.19
(0.165)
MAX.
1.780
(0.070)
MAX.
1.19
(0.047)
MAX.
2.540
(0.100)
BSC
DIMENSIONS IN MILLIMETERS (INCHES).
TOLERANCES (UNLESS OTHERWISE SPECIFIED): xx.xx = 0.01
xx.xxx = 0.005
HP 7820
YYWW
MOLDED
LEAD COPLANARITY
MAXIMUM: 0.102 (0.004)
*Refer to Option 300 Data Sheet for more information.
Maximum Solder Reflow Thermal Profile
240
T = 115°C, 0.3°C/SEC
0
T = 100°C, 1.5°C/SEC
T = 145°C, 1°C/SEC
TIME ­ MINUTES
TEMPERATURE ­ °C
220
200
180
160
140
120
100
80
60
40
20
0
260
1
2
3
4
5
6
7
8
9
10
11
12
(NOTE: USE OF NON-CHLORINE ACTIVATED FLUXES IS RECOMMENDED.)
1-236
Regulatory Information
The HCPL-7820/7825 has been
approved by the following
organizations:
UL
Recognized under UL 1577,
Component Recognition Program,
FILE E55361.
CSA
Approved under CSA Component
Acceptance Notice #5, File CA
88324.
VDE 0884 (06.92) Insulation Characteristics
Description
Symbol
Characteristic
Unit
Installation classification per DIN VDE 0110, Table 1
for rated mains voltage
300 V rms
I-IV
for rated mains voltage
600 V rms
I-III
Climatic Classification
40/100/21
Pollution Degree (DIN VDE 0110, Table 1)*
2
Maximum Working Insulation Voltage
V
IORM
848
V
peak
Input to Output Test Voltage, Method b**
V
PR
1591
V
peak
V
PR
= 1.875 x V
IORM
, Production test with t
p
= 1 sec,
Partial discharge < 5 pC
Input to Output Test Voltage, Method a**
V
PR
1273
V
peak
V
PR
= 1.5 x V
IORM
, Type and sample test with t
p
= 60 sec,
Partial discharge < 5 pC
Highest Allowable Overvoltage**
V
TR
6000
V
peak
(Transient Overvoltage t
TR
= 10 sec)
Safety-limiting values (Maximum values allowed in the event
of a failure, also see Figure 22)
Case Temperature
T
S
175
°
C
Input Power
P
S,Input
80
mW
Output Power
P
S,Output
250
mW
Insulation Resistance at T
S
, V
IO
= 500 V
R
S
1x10
12
*This part may also be used in Pollution Degree 3 environments where the rated mains voltage is
300 V rms (per DIN VDE 0110).
**Refer to the front of the optocoupler section of the current catalog for a more detailed description of VDE 0884 and other product
safety requirements.
Note: Optocouplers providing safe electrical separation per VDE 0884 do so only within the safety-limiting values to which they are
qualified. Protective cut-out switches must be used to ensure that the safety limits are not exceeded.
Insulation and Safety Related Specifications
Parameter
Symbol
Value
Units
Conditions
Min. External Air Gap
L(IO1)
7.4
mm
Measured from input terminals to output
(External Clearance)
terminals, shortest distance through air
Min. External Tracking Path
L(IO2)
8.0
mm
Measured from input terminals to output
(External Creepage)
terminals, shortest distance path along body
Min. Internal Plastic Gap
0.5
mm
Through insulation distance, conductor to
(Internal Clearance)
conductor, usually the direct distance
between the photoemitter and
photodetector inside the optocoupler
cavity
Tracking Resistance
CTI
175
V
DIN IEC 112/VDE 0303 Part 1
(Comparative Tracking
Index)
Isolation Group
III a
Material Group (DIN VDE 0110, 1/89,
Table 1)
Option 300 ­ surface mount classification is Class A in accordance with CECC 00802.
VDE
Approved according to VDE
0884/06.92.
1-237
Absolute Maximum Ratings
Parameter
Symbol
Min.
Max.
Unit
Note
Storage Temperature
T
S
-55
125
°
C
Ambient Operating Temperature
T
A
-
40
100
°
C
Supply Voltages
V
DD1
, V
DD2
0.0
5.5
V
Steady-State Input Voltage
V
IN+
, V
IN-
-2.0
V
DD1
+0.5
V
Two Second Transient Input Voltage
-6.0
Output Voltages
V
OUT+
, V
OUT-
-0.5
V
DD2
+0.5
V
Lead Solder Temperature
T
LS
260
°
C
1
(1.6 mm below seating plane, 10 sec.)
Reflow Temperature Profile
See Package Outline Drawings Section
Recommended Operating Conditions
Parameter
Symbol
Min.
Max.
Unit
Note
Ambient Operating Temperature
T
A
-40
100
°
C
Supply Voltages
V
DD1
, V
DD2
4.5
5.5
V
Input Voltage
V
IN+
, V
IN-
-200
200
mV